[page auto-refreshes after 300 sec]   [stop | on]            [press Ctrl+R to enforce refresh of scores and dates]
UVES trending system: HISTORY report
Last update: 2011-12-16T10:14:25 (UT)
same group: Res_U Res_L   Disp_U Disp_L   NLines_U NLines_L   WLmin_U WLmin_L   WLmax_U WLmax_L
close window history: 2003   2004   2005   2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024   HEALTH
  ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ...
*Date on this monitor changes at 21:00 UT
Print: Information and research:
- png file - advanced studies: QC1 browser | QC1 plotter
Plot
?
Symb
?
Source
*
Average ? Thresholds ? N_
data
QC1
parameter
Data
downloads
Remarks
method value unit method value
1 QC1DB MEAN 6834.88232 A none   75 lambda_max this | last_yr | all Maximum Wavelength for wavelength solution, from MOS WAVE data, 580.0 nm, 1x1, Plate 1, 7+1FIB Mode, Fibre 1, RED UPPER CCD. This parameter is not available in the opslogs.
2 QC1DB MEAN 6833.2041 A none   75 lambda_max this | last_yr | all same, for fibre 2
3 QC1DB MEAN 6830.86719 A none   75 lambda_max this | last_yr | all same, for fibre 3
4 QC1DB MEAN 6827.85303 A OFF± 20.0 75 lambda_max this | last_yr | all same, for fibre 4; this plot is scored.

5 QC1DB MEAN 6824.1167 A none   75 lambda_max this | last_yr | all same, for fibre 5
6 QC1DB MEAN 6820.74805 A none   75 lambda_max this | last_yr | all same, for fibre 6
7 QC1DB MEAN 6816.82471 A none   75 lambda_max this | last_yr | all same, for fibre 7
8 QC1DB MEAN 6811.92334 A none   75 lambda_max this | last_yr | all same, for fibre 8
*Data sources: QC1DB: QC1 database; LOCAL: local text file
Plot 1
data source:uves_fib_wave
(QC1 database)
dataset:lambda_max
mean:6834.88232A
thresholds:none 
N_data plotted:75
[click on plot for closeup]
Plot 2
data source:uves_fib_wave
(QC1 database)
dataset:lambda_max
mean:6833.2041A
thresholds:none 
N_data plotted:75
[click on plot for closeup]
Plot 3
data source:uves_fib_wave
(QC1 database)
dataset:lambda_max
mean:6830.86719A
thresholds:none 
N_data plotted:75
[click on plot for closeup]
Plot 4
data source:uves_fib_wave_scoreQC
(QC1 database)
dataset:lambda_max
mean:6827.85303A
rel. thresholds: 6807.85303...6847.85303A
N_data plotted:75
[click on plot for closeup]
Plot 5
data source:uves_fib_wave
(QC1 database)
dataset:lambda_max
mean:6824.1167A
thresholds:none 
N_data plotted:75
[click on plot for closeup]
Plot 6
data source:uves_fib_wave
(QC1 database)
dataset:lambda_max
mean:6820.74805A
thresholds:none 
N_data plotted:75
[click on plot for closeup]
Plot 7
data source:uves_fib_wave
(QC1 database)
dataset:lambda_max
mean:6816.82471A
thresholds:none 
N_data plotted:75
[click on plot for closeup]
Plot 8
data source:uves_fib_wave
(QC1 database)
dataset:lambda_max
mean:6811.92334A
thresholds:none 
N_data plotted:75
[click on plot for closeup]
This plot

This is the trending report for FLAMES/UVES QC parameters for wavelength calibration. It is based on data taken with the RED UPPER CCD in setting 580, 7+1FIB, with Plate 1. These data are taken daily as part of the Health Checks.

Note: only Fibre 5 is considered in the score for this report.
The individual plots describe:

  • Fibre 1: The average of the resolution values measured for each line included in the final selection
    Note that in contrast to fibres 2-8 which are illuminated by the robotic fibre projector fed by a Thorium-Argon lamp, fibre 1 is illuminated by the simultaneous calibration wavelength calibration lamp.
  • Fibres 2-8: The average of the resolution values measured for each line included in the final selection.

Note there is currently NO monitoring for fibre 9, used in the 8FIB modes.

User Manual specifications:

WL min_wav max_wav NMaxFib Gap [nm]

520 414 621 6 1

580 476 684 8 5

860 660 1060 8 10 Find more information about FLAMES/UVES wavelength solution monitoring here.  


General information

Click on any of the plots to see a close-up version. The latest date is indicated on top of the plot, data points belonging to that date are specially marked.

If configured,

  • statistical averages are indicated by a solid line, and thresholds by broken lines
  • outliers are marked by a red asterisk. They are defined as data points outside the threshold lines
  • "aliens" (= data points outside the plot Y limits) are marked by a red arrow ( or )
  • you can download the data for each parameter set if the 'Data downloads' link shows up