VIRCAM trending system: HEALTH CHECK report
HELP USERS-GUIDE MORE
Last update: 2013-05-18T21:35:01 (UT)
  | now: 2013-05-19T07:15:20 (UT) muc07 QC pipeline: vcam-1.3.2 (installed 2013-04-15)
same group: ELL_NB118 ELL_Z ELL_Y ELL_J ELL_H ELL_K
General news: Click 'scores&comments' to switch to score details, and 'HC plot' to switch back to the graphics.
VIRCAM news: 2013-05-10 : gradient over the FOV in PSF ellipticity found in STD on 2013-05-08 and on 2013-05-09
Report news: 2013-05-13 2013-05-10 The 8 left chips show higher ellipticity in STD frames in 2013-05-08 and 2013-05-09 [whummel@eso.org]
DATE*: [?] 2013-05-12
report | NLT
2013-05-13
report | NLT
2013-05-14
report | NLT
2013-05-15
report | NLT
2013-05-16
report | NLT
2013-05-17
report | NLT
2013-05-18
no data | NLT
P...
Product quality:
products products products products products products no products
  last OPSLOG data:
2013-05-18*

last files ...
monitor

scores&comments | FULL | history ... | plot tutorial ... | contact                 daily/often; important to check     [?]
*Date on this monitor changes at 21:00 UT
Print: Information and research:
- png file - advanced studies: QC1 browser | QC1 plotter
  • 2009-05-28: Scoring (red/green squares in the group bar and in the navigation bar) is on the detector average (Fig. 1) and detector rms (Fig. 3) values alone.
  • 2009-05-28: Scores of individual detector values (Fig. 4) are for detailed analysis but do not contribute to the overall instrument score.
Plot
?
Symb
?
Source
*
OPS?
**
Average ? Thresholds ? N_
data
QC1
parameter
Data
downloads
Remarks
method value unit method value
1 QC1DB yes (0) MEDIAN   none VAL0.02,0.3 0 qc_ellipticity this | last_yr | all PSF Ellipticity (1-b/a) K, average over all 16 detectors
2 QC1DB yes (0) MEDIAN   none VAL0.01,0.3 0 qc_ellipticity this | last_yr | all PSF Ellipticity (1-b/a) K, values of all detetcors
3 QC1DB yes (0) MEDIAN   none VAL0.0,0.1 0 qc_ellipticity this | last_yr | all PSF Ellipticity (1-b/a) K, stdev over all detectors
4 LOCAL no none   none none  0 qc_ellipticity n/a Score per Detector: Green = within the thresholds
4 LOCAL no none   none none  0 qc_ellipticity n/a Score per Detector: Red = beyond thresholds
4 .LOCAL no none   none none  0 qc_ellipticity n/a Score per Detector: Green = within the thresholds
4 .LOCAL no none   none none  0 qc_ellipticity n/a Score per Detector: Green = within the thresholds
*Data sources: QC1DB: QC1 database; LOCAL: local text file | **OPS: OPSLOG data are included
Plot 1
scores: 2|
data source:vircam_photstd
(QC1 database)
dataset:qc_ellipticity
median:no datanone
fixed thresholds:0.02...0.3none
N_data plotted:0
[click on plot for closeup]
Plot 2
scores: not implemented
data source:vircam_photstd
(QC1 database)
dataset:qc_ellipticity
median:no datanone
fixed thresholds:0.01...0.3none
N_data plotted:0
[click on plot for closeup]
Plot 3
scores: 2|
data source:vircam_photstd
(QC1 database)
dataset:qc_ellipticity
median:no datanone
fixed thresholds:0.0...0.1none
N_data plotted:0
[click on plot for closeup]
Plot 4
scores: not implemented
data source:local text file
dataset:
(numbers below apply to this dataset)
qc_ellipticity
average:none
thresholds:none
N_data plotted:0
[click on plot for closeup]
This plot

Trending plot for image quality.

QC parameters is derived from each detector of daily photometric standard star calibrations.

Name:
Fits header: QC ELLIPTICITY,
QC1 DB: qc_ellipticity

Description:
median ellipticity of the sources = (1-b/a).

Setup:
INS.FILT1.NAME = Ks

Note: Photometric standard standard star fields are acquired in AO.PRIORITY = NORMAL. This means the contraints

  • altitute difference between last telescope active optics loop and the photometric standard star field observations | TEL.AO.ALT - TEL.ALT | < DELTA.ALT degrees.
  • time between last telescope active optics loop and photometric standard star field observation ( DATE-OBS - TEL.AO.DATE ) < T minutes
do not apply.

These plots describe:
Fig. 1. Average view: The QC parameter averaged over all detectors. This view is sensitive to common changes.
Fig. 2. Resolved View: The QC parameter resolved for all detectors.
Fig. 3. Scatter View: The standard deviation of the QC parameter, obtained from the sample of all detectors. This view is sensitive changes of individual detectors.
Fig. 4. Scoring View: Scoring values of all 16 QC parameters. Green = within the acceptance thresholds. Red = beyond the acceptance thresholds.

Find more information on the VIRCAM STD tutorial page.

 


General information

Click on any of the plots to see a close-up version.

If applicable, the latest values from Paranal ops logs are plotted as blue dots. More information about those values, including a download option, is available in the OPS column.

The latest date is indicated on top of the plot, data points belonging to that date are specially marked.

If configured,

  • statistical averages are indicated by a solid line, and thresholds by broken lines
  • outliers are marked by a red asterisk. They are defined as data points outside the threshold lines
  • "aliens" (= data points outside the plot Y limits) are marked by a red arrow ( or )
  • you can download the data for each parameter set if the 'Data downloads' link shows up