Description:
Centers the target object on the telescope field using the Autoguiding
error vector evaluation fuctions
Role(s)/Actor(s):
Primary: Operator,Maintenance
Secondary: FAS/FSS sub-system, tracking axes
Priority: Desirable
Performance: 30 seconds
Frequency: At preset time
Preconditions:
- ATCS is ONLINE Tracking
- AG / FS are Idle
- FAS is ONLINE
- Coude Beam Switching device allows light path to FAS/FSS
- a Guide Reference Point is defined
Basic Course:
- Send command CNTOBJto start Object Centering
Exception course: Command failed
- ATCS Sets Guide Reference Point to center field.
Exception Course: Command failed
- ATCS performs Center Guide Star automatic centering with the
FAS/FSS. Since the guide reference point is set to center field, the
target is used in place of the guide star.
Exception Course: Command failed
- ATCS Sets Guide Reference Point to original value.
Exception Course: Command failed
- ATCS returns OK reply
Exception Course: Command failed
Postconditions:
- Target object is centered in the field of view
Issues to be Determined or Resolved:
Notes:
Last modified: Thu Dec 20 15:21:58 UTC 2001