Use Case:
Monitor Cabinet Cooling Module Status & Temperatures
Description:
Check periodically the Cabinet Cooling Module status and temperatures
Role(s)/Actor(s):
Primary: TRS
Secondary: Altitude Cabinet Cooling Module
Priority: Major
Performance: TBD
Frequency: once per minute
Preconditions:
- ATCS state is STANDBY or ONLINE
Basic Course:
- TRS triggers the readout of the CCM Status and Temperatures
(Cabinet and Ambient)
Exception Course: Command failed
- ATCS sends command to the Altitude Cabinet Cooling Module sub-system
Exception Course: Communication failed
Exception Course: Command failed
- ATCS updates the status and temperatures of the Cabinet Cooling Module sub-system
- ATCS checks the CCM status
- Subflow: CCM Status failure
- ATCS checks the cabinet internal temperature against limit
- Subflow: Over temperature
Subflow: CCM Status failure
- ATCS logs the error
- ATCS raises an alarm
Subflow: Over temperature
- ATCS logs the error
- ATCS raises an alarm
Exception Course: Communication failed
- ATCS logs the error
- ATCS set the module to subState Error
Exception Course: Command failed
Postconditions:
- The status and temperatures of the Cabinet Cooling Module are monitored periodically
Issues to be Determined or Resolved:
Notes:The temperatures shall be fits-logged for trend
analysis.