mirror sites: PL (internal link) HQ     [?]

Health Check monitor

 

CAL | HC | refs | QC
HealthCheck Monitor
   HOME | UsersGuide
  sl icon ALL INSTRUMENTS
 
FULL reports
AMBER
P2VM Low Res
Other HC:
QC links:
        [page auto-refreshes after 300 sec]   [stop | on]            [press Ctrl+Shift+R to enforce refresh of scores, dates and news]
AMBER trending system: SCORES (quick-look)
HELP USERS-GUIDE MORE
Last update: 2014-07-28T13:15:08 (UT)
  | now: 2014-07-28T13:32:45 (UT) muc05 QC pipeline: amber-4.3.1 (installed 2014-03-19)
same group: P2VM_LJHK K_P2VM_LJHK H_P2VM_LJHK J_P2VM_LJHK
General news:
AMBER news:
Report news: 2014-07-23 Bas12: the lower threshold was slightly decreased (H band int Vis lower than previously with new niobates plates) [ipercher@eso.org]
DATE*: [?] 2014-07-21
report | NLT
2014-07-22
report | NLT
2014-07-23
report | NLT
2014-07-24
report | NLT
2014-07-25
report | NLT
2014-07-26
report | NLT
2014-07-27
report | NLT
P...
Product quality:
products no products products products no products no products no products
  last OPSLOG data:
2014-07-24*

monitor

HC plot | FULL | history ... | plot tutorial ... | contact                 daily/often; important to check     [?]
*Date on this monitor changes at 21:00 UT
Internal Vis LR in JHK (over full range) (scores, last 7 days up to 2014-07-24*)
1: JHK_bas12
16|
2: JHK_bas23
16|
3: JHK_bas31
16|
Quality comments:
Plot Date* AB name (linked to score report) score product quality comment
Plot 12014-07-18AMBER.2014-07-18T21:56:41.969_tpl.ab
low int Vis for 1 baseline
Plot 12014-07-18AMBER.2014-07-18T22:10:18.365_tpl.ab
low int Vis for 2 bas, test calib
Plot 12014-07-18AMBER.2014-07-18T22:55:11.815_tpl.ab
low int Vis for 2 bas
Plot 12014-07-18AMBER.2014-07-18T23:52:16.310_tpl.ab
low int Vis for 2 bas, test calib
Plot 12014-07-18AMBER.2014-07-19T03:20:14.489_tpl.ab
low int Vis for 1 baseline, used only to calibrate astro calib test data
Plot 12014-07-19AMBER.2014-07-19T22:45:33.736_tpl.ab
OK, tests
Plot 12014-07-19AMBER.2014-07-19T22:58:09.526_tpl.ab
OK, tests
Plot 22014-07-18AMBER.2014-07-18T21:56:41.969_tpl.ab
low int Vis for 1 baseline
Plot 22014-07-18AMBER.2014-07-18T22:10:18.365_tpl.ab
low int Vis for 2 bas, test calib
Plot 22014-07-18AMBER.2014-07-18T22:55:11.815_tpl.ab
low int Vis for 2 bas
Plot 22014-07-18AMBER.2014-07-18T23:52:16.310_tpl.ab
low int Vis for 2 bas, test calib
Plot 22014-07-18AMBER.2014-07-19T03:20:14.489_tpl.ab
low int Vis for 1 baseline, used only to calibrate astro calib test data
Plot 22014-07-19AMBER.2014-07-19T22:45:33.736_tpl.ab
OK, tests
Plot 22014-07-19AMBER.2014-07-19T22:58:09.526_tpl.ab
OK, tests
Plot 32014-07-18AMBER.2014-07-18T21:56:41.969_tpl.ab
low int Vis for 1 baseline
Plot 32014-07-18AMBER.2014-07-18T22:10:18.365_tpl.ab
low int Vis for 2 bas, test calib
Plot 32014-07-18AMBER.2014-07-18T22:55:11.815_tpl.ab
low int Vis for 2 bas
Plot 32014-07-18AMBER.2014-07-18T23:52:16.310_tpl.ab
low int Vis for 2 bas, test calib
Plot 32014-07-18AMBER.2014-07-19T03:20:14.489_tpl.ab
low int Vis for 1 baseline, used only to calibrate astro calib test data
Plot 32014-07-19AMBER.2014-07-19T22:45:33.736_tpl.ab
OK, tests
Plot 32014-07-19AMBER.2014-07-19T22:58:09.526_tpl.ab
OK, tests
"Date" links to complete AB product page; "AB" links to score report


Scores

This is the quick-look version of the HealthCheck (HC) Monitor. It displays scores for each HC report. Scores are flags assessing the compliance of data points with configured thresholds. A green score indicates that the corresponding instrument component is performing as expected (OK) in the monitored time range. A red score is the result of a parameter exceeding these thresholds, and may indicate a problem.

Scoring has both an automatic and an interactive component. The automatic part consists of monitoring, pipeline-processing, and flagging new data once per hour, 24/7. The interactive component is the certification step which is performed by the QC scientist. It involves the analysis of red scores: A confirmation of their validity, an assessment of the severity of the red score and its cause, and often an analysis comment in the AB monitor. In cases of serious instrument issues, feedback to Paranal operations and/or USD is given. However, this analysis step cannot be guaranteed to be available at the same time as the automatic scoring. Do not expect new analysis results during weekends, holidays or other off-duty times.

The last score, per plot, will determine the current plot score, which is displayed as a larger symbol. The other, older plot scores display only the recent history of instrument scores. As part of the automatic scoring, a red score will be automatically overwritten by any new data that produce a green score. The date of any score can be seen by mousing over its score symbol. As part of the interactive analysis, there is also the possibility for the QC scientist to manually adjust thresholds and turn a red score into a green one, or to delete a false red score. Often this occurs after interaction with Paranal staff, after discussing the significance of the alert score. Use the 'contact' link to get in touch.

If available, a table with quality comments is displayed on the scores&comments page, usually offering additional information about data with red scores. A comment may refer to the quality of the pipeline products and not necessarily to the exact parameter scored in this report. Quality comments are entered by the QC scientist as part of the analysis workflow.

Scores are based on the QC data for the last 7 days before the indicated date. This date is always the last date with data for this report.

Information on demand:
- scroll over the small symbols and see the individual dates of the underlying data.
- click on them and see the detailed score report for that particular data set.

More ...