[all links are internal]             [page auto-refreshes after 300 sec]   [stop | on]            [press Ctrl+Shift+R to enforce refresh of "ago" time information]
CAL
FORS2 calChecker: calibration completeness monitor
Last update: 2019-12-06T23:55:55 (UT)
[?]
  Paranal date*: 2019-12-06         muc01 [?]   server: HQ PL
HELP ASSOC-RULES DETAILS
Last header: FORS2. 2019-12-06T23:14:30.236.hdr
       [?]
  *Date on this monitor changes at 21:00 UT. Refresh frequency: 1/2hr day and night
General news:
Long-term calibrations and maintenance complete overview | how to execute     [?]
type of calibration validity (days) age (days) evaluation
DARK_high_gain_MIT14 10.9soft REMINDER: next 7 day(s)
DETECTOR_MON_high_gain_2x2_MIT30 22.2soft REMINDER: next 16 day(s)
DETECTOR_MON_low_gain_1x1_MIT30 22.2soft REMINDER: next 16 day(s)
FORS2 news:

       

HELP | Q&A | ASSOC-RULES   history... | contact   monitors: DataTransferMonitor | BandWidth
  science  .   cal4cal  .    [?]     Product availability depends on the data transfer to Garching and the archive access there (check the "transfer" and "ngas" flags above).
  daytime calibs: finished 10:37UT
DATE*:   [?]
[color if science data acquired]
2019-11-29
SM VM
68
report | NLT
2019-11-30
SM VM
114
report | NLT
2019-12-01
SM VM
134
report | NLT
2019-12-02
SM
28
report | NLT
2019-12-03

report | NLT
2019-12-04
SM
70
report | NLT
2019-12-05
SM
24
report | NLT
2019-12-06

report | NLT
LOST?
[may require OB
grade review]
Calibration action?     [?]
[take these data types ...
Setup:
... for these setups]
r...
Raw CAL displays:     [?]
raw raw raw raw raw raw raw no CAL raw files      
P...
CAL product quality:     [?]
products products products products products products products no CAL products      
Data types: Setup:        
SCI_IMG 200Kps/low_SR_2x2  
 
 
 
 
 
ok
analyzed: [1]
 
  all ok  
200Kps/low_SR_I_BESS_2x2  
 
ok
 
 
ok
 
 
  all ok  
200Kps/low_SR_R_SPECIAL_2x2  
ok
ok
ok
 
ok
 
 
  all ok  
200Kps/low_SR_b_HIGH_2x2  
 
ok
 
 
ok
 
 
  all ok  
200Kps/low_SR_v_HIGH_2x2  
 
ok
 
 
ok
 
 
  all ok  
SCI_MXU 100Kps/high_SR_GG435_G300V_+932556_2x2  
 
 
ok
 
ok
 
 
  all ok  
100Kps/high_SR_OG590_G300I_+921539_2x2  
 
 
 
 
 
ok
 
  all ok  
100Kps/high_SR_OG590_G300I_+921622_2x2 ok
 
 
 
 
 
 
 
  all ok  
100Kps/high_SR_OG590_G300I_+985755_2x2  
 
 
ok
 
ok
 
 
  all ok  
SCI_LSS 100Kps/high_SR_G300V_1_0_2x2  
 
ok
 
 
ok
 
 
  all ok  
100Kps/high_SR_G300V_2_0_2x2  
 
 
 
 
ok
analyzed: [2]
 
 
  all ok  
100Kps/high_SR_OG590_G300I_1_0_2x2  
ok
ok
 
 
ok
 
 
  all ok  
SCI_PMOS 100Kps/high_SR_G300V_RETA2_0_2x2  
 
 
 
 
ok
 
 
  all ok  
200Kps/low_SR_GG435_G300V_RETA2_0_2x2 ok
ok
ok
 
 
 
 
 
  all ok  
ANALYSIS NOTES:
Index data type setup date flag analysis
[1]SCI_IMG200Kps/low_SR_2x22019-12-05OKscience OB was graded C, no further calibrations required (analyzed by antu@eso.org)
[2]SCI_LSS100Kps/high_SR_G300V_2_0_2x22019-12-04OKuser privided flux standard (analyzed by smieske@eso.org)
 
INFORMATION SPECIFIC TO FORS2           [?]
The following keys are used to define a SCIENCE FORS2 setup:

det.read.clock (e.g. 100Kps/2ports/high_gain, 200Kps/2ports/low_gain, 625Kps/2ports/low_gain)
ins.coll.name (= SR, HR)
ins.opti#.name (# = 5,6,7,9,10; polarization optics, grisms e.g. G300V, and filters e.g. GG435)
ins.slit.name (long slit name)
ins.mos.checksum (identification of MOS setup)
ins.mask.id (identification of MXU mask, e.g. +905221)
det.win1.binx,det.win1.biny (= 1x1, 2x2)

CONFIGURATION           [?]
Number of days scanned: 7
Range of days for the issue memory (configured): 15
Range of days for the calibration memory (issue memory plus longest validity): 22
Days in the calibration&issue memory:
*Date on this monitor changes at: 21:00 UT
powered by QC [calChecker v4.6.7]   increm