mirror sites: PL (internal link) HQ     [?]

Calibration completeness monitor

 

[all links are internal]             [page auto-refreshes after 300 sec]   [stop | on]            [press Ctrl+Shift+R to enforce refresh of "ago" time information]
CAL | HC | refs | QC
CALCHECKER
  HOME | HELP
  sl icon ALL INSTRUMENTS
FORS2
QC links:
CAL
FORS2 calChecker: calibration completeness monitor
Last update: 2017-02-24T18:26:22 (UT)
[?]
  Paranal date*: 2017-02-23         muc01 [?]   server: www.eso.org HQ
HELP ASSOC-RULES DETAILS
Last header: FORS2. 2017-02-24T15:31:13.617.hdr
transfer     ngas    [?]
  *Date on this monitor changes at 21:00 UT. Refresh frequency: 1/2hr day and night
General news:
Long-term calibrations and maintenance complete overview | how to execute     [?]
type of calibration validity (days) age (days) evaluation
DARK_low_gain_MIT14 16.1REMINDER: take as soon as possible
DARK_high_gain_MIT14 16.1REMINDER: take as soon as possible
DETECTOR_MON_high_gain_2x2_MIT30 31.6REMINDER: take as soon as possible
DETECTOR_MON_low_gain_2x2_MIT30 31.6REMINDER: take as soon as possible
DETECTOR_MON_low_gain_1x1_MIT30 31.6REMINDER: take as soon as possible
FORS2 news:

       

HELP | Q&A | ASSOC-RULES   history... | contact   monitors: DataTransferMonitor | BandWidth
  science  .   cal4cal  .    [?]     Product availability depends on the data transfer to Garching and the archive access there (check the "transfer" and "ngas" flags above).
  daytime calibs: finished 11:10UT
DATE*:   [?]
[color if science data acquired]
2017-02-17

report | NLT
2017-02-18

report | NLT
2017-02-19
VM
52
report | NLT
2017-02-20
VM
86
report | NLT
2017-02-21
VM
32
report | NLT
2017-02-22
VM
32
report | NLT
2017-02-23
SM
26
report | NLT
LOST?
[may require OB
grade review]
Calibration action?     [?]
[take these data types ...
Setup:
... for these setups]
r...
Raw CAL displays:     [?]
no raw files no raw files raw raw raw raw raw      
P...
Product quality:     [?]
no products no products products products products products products      
Data types: Setup:        
SCI_IMG 200Kps/low_HR_b_HIGH_Norma_2x2  
 
ok
ok
 
 
 
  all ok  
200Kps/low_HR_u_HIGH_Norma_2x2  
 
ok
analyzed: [1]
ok
analyzed: [2]
 
 
 
  all ok  
200Kps/low_SR_FILT_388_4_Norma_2x2  
 
 
ok
 
 
 
  all ok  
200Kps/low_SR_Norma_2x2  
 
 
ok
analyzed: [3]
 
 
 
  all ok  
200Kps/low_SR_OII/4000_Norma_2x2  
 
 
ok
 
 
 
  all ok  
SCI_MXU 100Kps/high_SR_G300V_+901050_Norma_2x2  
 
 
 
ok
ok
 
  all ok  
100Kps/high_SR_G300V_+902655_Norma_2x2  
 
 
 
 
ok
 
  all ok  
100Kps/high_SR_OG590_G300I_+901050_Norma_2x2  
 
 
 
 
ok
 
  all ok  
SCI_LSS 100Kps/high_SR_G1200B_1_0_Norma_2x2  
 
 
 
 
 
miss
[daycals finished; problem not yet analyzed]
  STD_MOS 100Kps/high_SR_G1200B_1_0_Norma_2x2
100Kps/high_SR_G300V_1_0_Norma_2x2  
 
 
 
ok
ok
 
  all ok  
100Kps/high_SR_G600B_2_5_Norma_2x2  
 
 
ok
 
 
 
  all ok  
100Kps/high_SR_OG590_G300I_1_0_Norma_2x2  
 
 
 
ok
ok
 
  all ok  
ANALYSIS NOTES:
Index data type setup date flag analysis
[1]SCI_IMG200Kps/low_HR_u_HIGH_Norma_2x22017-02-19OKscience OB does not require a standard (changed to OK by qc_vimos@eso.org)
[2]SCI_IMG200Kps/low_HR_u_HIGH_Norma_2x22017-02-20OKscience OB does not require a standard (changed to OK by qc_vimos@eso.org)
[3]SCI_IMG200Kps/low_SR_Norma_2x22017-02-20OKWrong image (VM), no calibration needed (analyzed by bdias@eso.org)
 
INFORMATION SPECIFIC TO FORS2           [?]
The following keys are used to define a SCIENCE FORS2 setup:

det.win1.binx,det.win1.biny (= 1, 2)
det.read.clock (= 100Kps/2ports/high_gain, 200Kps/2ports/low_gain, 625Kps/2ports/low_gain)
ins.coll.name (= SR, HR)
ins.opti#.name (# = 5,6,7,9,10; polarization optics, grisms, and filters )
ins.slit.name (long slit name)
ins.mos.checksum (identification of MOS setup)
ins.mask.id (identification of MXU mask)
det.chip1.id (= CCID20-14-5-3, CCID20-14-5-6)

CONFIGURATION           [?]
Number of days scanned: 7
Range of days for the issue memory (configured): 15
Range of days for the calibration memory (issue memory plus longest validity): 22
Days in the calibration&issue memory:
*Date on this monitor changes at: 21:00 UT
powered by QC [calChecker v4.6.1]   increm