mirror sites: PL (internal link) HQ     [?]

Calibration completeness monitor

 

[all links are internal]             [page auto-refreshes after 300 sec]   [stop | on]            [press Ctrl+Shift+R to enforce refresh of "ago" time information]
CAL | HC | refs | QC
CALCHECKER
  HOME | HELP
  sl icon ALL INSTRUMENTS
FORS2
QC links:
CAL
FORS2 calChecker: calibration completeness monitor
Last update: 2018-04-27T03:14:39 (UT)
[?]
  Paranal date*: 2018-04-26         muc01 [?]   server: www.eso.org HQ
HELP ASSOC-RULES DETAILS
Last header: FORS2. 2018-04-26T20:28:17.623.hdr
transfer     ngas    [?]
  *Date on this monitor changes at 21:00 UT. Refresh frequency: 1/2hr day and night
General news:
Long-term calibrations and maintenance complete overview | how to execute     [?]
type of calibration validity (days) age (days) evaluation
DARK_low_gain_MIT14 12.4soft REMINDER: next 5 day(s)
DARK_high_gain_MIT14 13.5soft REMINDER: next 4 day(s)
DETECTOR_MON_high_gain_2x2_MIT30 30.6REMINDER: take as soon as possible
DETECTOR_MON_low_gain_2x2_MIT30 30.6REMINDER: take as soon as possible
DETECTOR_MON_low_gain_1x1_MIT30 30.6REMINDER: take as soon as possible
FORS2 news:

       

HELP | Q&A | ASSOC-RULES   history... | contact   monitors: DataTransferMonitor | BandWidth
  science  .   cal4cal  .    [?]     Product availability depends on the data transfer to Garching and the archive access there (check the "transfer" and "ngas" flags above).
  daytime calibs:   pending
DATE*:   [?]
[color if science data acquired]
2018-04-20
SM
18
report | NLT
2018-04-21

report | NLT
2018-04-22
SM
4
report | NLT
2018-04-23

report | NLT
2018-04-24

report | NLT
2018-04-25

report | NLT
2018-04-26

no data | NLT
LOST?
[may require OB
grade review]
Calibration action?     [?]
[take these data types ...
Setup:
... for these setups]
r...
Raw CAL displays:     [?]
raw raw raw raw raw raw no CAL raw files      
P...
CAL product quality:     [?]
products products products products products products no CAL products      
Data types: Setup:        
SCI_IMG 200Kps/low_SR_FILT_815_13_2x2  
 
 
 
 
 
no data (yet)   all ok  
SCI_MXU_1 200Kps/low_SR_GG435_G600RI_+951634_2x2  
 
 
 
 
 
    all ok  
200Kps/low_SR_GG435_G600RI_+951914_2x2  
 
 
 
 
 
    all ok  
SCI_LSS 100Kps/high_SR_G1200B_0_7_2x2  
 
ok
 
 
 
    all ok  
100Kps/high_SR_G300V_0_7_2x2  
 
 
 
 
 
    all ok  
100Kps/high_SR_G600B_1_0_2x2 ok
 
ok
 
 
 
    all ok  
100Kps/high_SR_GG435_G1200R_1_0_2x2 ok
 
 
 
 
 
    all ok  
SCI_LSS_1 100Kps/high_SR_G600B_0_3_1x1 ok
 
 
 
 
 
    all ok  
 
INFORMATION SPECIFIC TO FORS2           [?]
The following keys are used to define a SCIENCE FORS2 setup:

det.read.clock (e.g. 100Kps/2ports/high_gain, 200Kps/2ports/low_gain, 625Kps/2ports/low_gain)
ins.coll.name (= SR, HR)
ins.opti#.name (# = 5,6,7,9,10; polarization optics, grisms e.g. G300V, and filters e.g. GG435)
ins.slit.name (long slit name)
ins.mos.checksum (identification of MOS setup)
ins.mask.id (identification of MXU mask, e.g. +905221)
det.win1.binx,det.win1.biny (= 1x1, 2x2)

CONFIGURATION           [?]
Number of days scanned: 7
Range of days for the issue memory (configured): 15
Range of days for the calibration memory (issue memory plus longest validity): 22
Days in the calibration&issue memory:
*Date on this monitor changes at: 21:00 UT
powered by QC [calChecker v4.6.5]   full