GIRAFFE trending system: HISTORY plot
Last update: 2007-10-15T14:56:19 (UT)
same group: SIM-lamp FF-lamp ARC-lamp   NAS-lamp
close window history: 2003   2004   2005   2006 2007 2008 2009 2010 2011 2012   HEALTH
  ... ... ... ... ... ... ...
*Date on this monitor changes at 21:00 UT
Print: Information and research:
- png file - advanced studies: QC1 browser | QC1 plotter
Plot
[info]
Symbol
[info]
Source* Average [info] Thresholds [info] N_data Data downloads Remarks
method value unit method value
1 QC1DB none   counts/sec none   72 this | last_yr | all flux of SIMCAL lamp, Medusa1
2 QC1DB none   counts/sec none   71 this | last_yr | all as plot 1, Medusa2
3 QC1DB none   counts/sec none   72 this | last_yr | all as plot 1, IFU1
4 QC1DB none   counts/sec none   71 this | last_yr | all as plot 1, IFU2
5 QC1DB none   counts/sec none   71 this | last_yr | all as plot 1, Argus

7 QC1DB MEAN 1.391 ratio to Medusa1 3SIG± 0.063 70   computed ratio Med2/Med1
(no data available for download)
8 QC1DB MEAN 0.396 same 3SIG± 0.047 69   as plot 7, IFU1/Medusa1
9 QC1DB MEAN 0.308 same 3SIG± 0.153 68   as plot 7, IFU2/Medusa1
10 QC1DB MEAN 0.577 same 3SIG± 0.103 68   as plot 7, Argus/Medusa1
*Data sources: QC1DB: QC1 database; LOCAL: local text file
This plot

This is the trending plot monitoring the stability of the GIRAFFE SIMCAL arclamp and the 5 fibre systems. These data are derived from the daily SIMLAMP,TAL health check measurements (5 with the HR grating, H525.8B setting).

Plots 1-5.For each of the five fibre systems, an emission line is selected, its intensity is integrated and divided by the EXPTIME. The resulting flux, in counts/sec, is trended over time.

Plots 7-10. 4 slit systems are ratioed against the Medusa1 system. Since all slits are illuminated by the same lamp, lamp effects cancel out, while effects of the specific fibre system are enhanced.

If a certain trend effect is visible in *all* four slits, it is likely to occur in Medusa1. If it shows up in one fibre system only, it originates in that particular slit.

Find more information here. The SIMLAMP data are also used to evaluate the grating stability.

 
General information

Click on any of the plots to see a close-up version. The latest date is indicated on top of the plot, data points belonging to that date are specially marked.

If configured,

  • statistical averages are indicated by a solid line, and thresholds by broken lines
  • outliers are marked by a red asterisk. They are defined as data points outside the threshold lines
  • "aliens" (= data points outside the plot Y limits) are marked by a red arrow ( or )
  • you can download the data for each parameter set if the 'Data downloads' link shows up