[page auto-refreshes after 300 sec]   [stop | on]            [press Ctrl+R to enforce refresh of scores and dates]
NACO trending system: HEALTH CHECK report
Last update: 2012-05-26T02:26:48 (UT)
| now: 2012-05-26T04:02:40 (UT)
HELP USERS-GUIDE MORE
same group: hot/cold_pixels gain FPN
General news: 2012-05-24: The HC monitors for OMEGACAM, VIRCAM and HAWKI are back. Population with current data is in progress.
NACO news:
Report news: 2012-02-10: 8-column noise problem in the upper half of the detector causes higher fixed pattern noise
DATE*: [?] 2012-05-19
report | NR
2012-05-20
report | NR
2012-05-21
report | NR
2012-05-22
report | NR
2012-05-23
report | NR
2012-05-24
report | NR
2012-05-25
report | NR
P...
Product quality:
products products products products products products products
  no OPSLOG data  
close window history: 2004 2005 2006 2007 2008 2009 2010 2011   2012   HEALTH
  ... ... ... ... ... ... ...
*Date on this monitor changes at 21:00 UT
Print: Information and research:
- png file - advanced studies: QC1 browser | QC1 plotter
Plot
?
Symb
?
Source
*
OPS?
**
Average ? Thresholds ? N_
data
QC1
parameter
Data
downloads
Remarks
method value unit method value
1 QC1DB no MEAN 40.40392   VAL22,62 123 fpn this | last_yr | all fixed-pattern-noise from lampflats taken with Double_RdRstRd mode
2 QC1DB no MEAN 38.63423   VAL30,56 32 fpn this | last_yr | all fixed-pattern-noise from lampflats taken with FowlerNsamp mode
*Data sources: QC1DB: QC1 database; LOCAL: local text file | **OPS: to indicate that OPSLOG data are included
Plot 1
scores: 36|
data source:naco_lampflat
(QC1 database)
dataset:fpn
mean:40.40392 
fixed thresholds:22.0...62.0 
N_data plotted:123
[click on plot for closeup]
Plot 2
scores: 5|
data source:naco_lampflat
(QC1 database)
dataset:fpn
mean:38.63423 
fixed thresholds:30.0...56.0 
N_data plotted:32
[click on plot for closeup]
This plot

Fixed-Patter-Noise - the largest noise component in the raw frames of the lamp flat-fields. It is determined by the "naco_img_lampflat" recipe of the NACO pipeline (QC.FPNOISE). The data points are separated by the detector readout mode the lampflats were taken with.  


General information

Click on any of the plots to see a close-up version. The latest date is indicated on top of the plot, data points belonging to that date are specially marked.

If configured,

  • statistical averages are indicated by a solid line, and thresholds by broken lines
  • outliers are marked by a red asterisk. They are defined as data points outside the threshold lines
  • "aliens" (= data points outside the plot Y limits) are marked by a red arrow ( or )
  • you can download the data for each parameter set if the 'Data downloads' link shows up