mirror sites: PL (internal link) HQ     [?]

Health Check monitor

 

CAL | HC | refs | QC
HealthCheck Monitor
   HOME | UsersGuide
  sl icon ALL INSTRUMENTS
 
FULL reports
VIRCAM:
twilight flat : range
Other HC:
QC links:
        [page auto-refreshes after 300 sec]   [stop | on]            [press Ctrl+Shift+R to enforce refresh of scores, dates and news]
VIRCAM trending system: HEALTH CHECK report
HELP USERS-GUIDE MORE
Last update: 2014-10-26T00:53:55 (UT)
  | now: 2014-10-26T03:43:01 (UT) muc07 QC pipeline: vcam-1.3.3 (installed 2014-10-20)
same group: MinMax_NB980 NB118 _Z _Y _J _H _K   RANGE_NB980 NB118 _Z _Y _J _H _K
General news:
VIRCAM news:  
Report news:
DATE*: [?] 2014-10-19
report | NLT
2014-10-20
report | NLT
2014-10-21
report | NLT
2014-10-22
report | NLT
2014-10-23
report | NLT
2014-10-24
report | NLT
2014-10-25
report | NLT
P...
Product quality:
products products products products products products products
  last OPSLOG data:
2014-10-22*

monitor

scores&comments | history ... | plot tutorial ... | contact               [?]
*Date on this monitor changes at 21:00 UT
Print: Information and research:
- png file - advanced studies: QC1 browser | QC1 plotter
Plot
?
Symb
?
Source
*
OPS?
**
Average ? Thresholds ? N_
data
QC1
parameter
Data
downloads
Remarks
method value unit method value
1 QC1DB yes (3) none   ADU none  11 qc_twflat_medmin this | last_yr | all TWILRAWMINMAX, average over all 16 detectors
1 QC1DB yes (3) none   ADU VAL4000,12000 11 qc_twflat_medavg this | last_yr | all TWILRAWMINMAX, average over all 16 detectors
1 QC1DB yes (3) none   ADU none  11 qc_twflat_medmax this | last_yr | all TWILRAWMINMAX, average over all 16 detectors
2 QC1DB yes (48) none   ADU none  176 qc_twflat_medmin this | last_yr | all TWILRAWMINMAX, values of all detetcors
2 oQC1DB yes (48) none   ADU VAL4000,12000 176 qc_twflat_medavg this | last_yr | all TWILRAWMINMAX, values of all detetcors
2 QC1DB yes (48) none   ADU none  176 qc_twflat_medmax this | last_yr | all TWILRAWMINMAX, values of all detetcors
3 QC1DB yes (3) none   ADU none  11 qc_twflat_medmin this | last_yr | all TWILRAWMINMAX, stdev over all detectors
3 QC1DB yes (3) none   ADU none  11 qc_twflat_medavg this | last_yr | all TWILRAWMINMAX, stdev over all detectors
3 QC1DB yes (3) none   ADU none  11 qc_twflat_medmax this | last_yr | all TWILRAWMINMAX, stdev over all detectors
*Data sources: QC1DB: QC1 database; LOCAL: local text file | **OPS: OPSLOG data are included
Plot 1
scores: not implemented
data source:vircam_twilight
(QC1 database)
dataset:
(numbers below apply to this dataset)
qc_twflat_medmin
average:none
thresholds:none
N_data plotted:11
[click on plot for closeup]
Plot 2
scores: not implemented
data source:vircam_twilight
(QC1 database)
dataset:
(numbers below apply to this dataset)
qc_twflat_medmin
average:none
thresholds:none
N_data plotted:176
[click on plot for closeup]
Plot 3
scores: not implemented
data source:vircam_twilight
(QC1 database)
dataset:
(numbers below apply to this dataset)
qc_twflat_medmin
average:none
thresholds:none
N_data plotted:11
[click on plot for closeup]
This plot

Trending plot for Minimum, Average, and Maximum of raw frame medians.

QC parameters is derived from the twilight flat raw frame input stack.

Name:QC_RAWMED_AVG
Fits header: QC.FLATMIN, QC.FLATAVG, QC.FLATMAX
QC1 DB: qc_twflat_medmin, qc_twflat_medavg, qc_twflat_medmax
Description:
Retrieve from each raw frame the median of the flux level. Take the average, the maximum mand the minimum of the sample of all raw frame medians.

Setup:
INS.FILT1.NAME = K

These plots describe:
Fig. 1. Average view: The QC parameter averaged over all detectors. This view is sensitive to common changes.
Fig. 2. Resolved View: The QC parameter resolved for all detectors.
Fig. 3. Scatter View: The standard deviation of the QC parameter, obtained from the sample of all detectors. This view is sensitive changes of individual detectors.
Fig. 4. Extra: PRO.DATANCOM, the number of raw frames which contributed to the master twilight flat.

Find more information on the VIRCAM TWILIGHT FLAT tutorial page.

 


General information

Click on any of the plots to see a close-up version.

If applicable, the latest values from Paranal ops logs are plotted as blue dots. More information about those values, including a download option, is available in the OPS column.

The latest date is indicated on top of the plot, data points belonging to that date are specially marked.

If configured,

  • statistical averages are indicated by a solid line, and thresholds by broken lines
  • outliers are marked by a red asterisk. They are defined as data points outside the threshold lines
  • "aliens" (= data points outside the plot Y limits) are marked by a red arrow ( or )
  • you can download the data for each parameter set if the 'Data downloads' link shows up