mirror sites: PL (internal link) HQ     [?]

Health Check monitor

 

CAL | HC | refs | QC
HealthCheck Monitor
   HOME | UsersGuide
  sl icon ALL INSTRUMENTS
 
all KPI reports
UVES:
detector: monitoring
Other HC:
QC links:
        [page auto-refreshes after 300 sec]   [stop | on]            [press Ctrl+Shift+R to enforce refresh of scores, dates and news]
UVES trending system: HEALTH CHECK report
HELP USERS-GUIDE MORE
Last update: 2024-04-28T06:02:14 (UT)
  | now: 2024-04-28T10:56:35 (UT) muc02 QC pipeline: uves-6.1.11 (installed 2023-06-22)
same group: dark linearity gain duty_cycle
General news: NOTE: The Health Check and calChecker services are moved to qcFlow on an instrument by instrument basis. The current pages will not be updated any longer once the move has been finished.
UVES news:  
Report news:
DATE*: [?] 2024-04-21
report | NLT
2024-04-22
report | NLT
2024-04-23
report | NLT
2024-04-24
report | NLT
2024-04-25
report | NLT
2024-04-26
report | NLT
2024-04-27
report | NLT
r...
Raw CAL displays:
raw raw raw raw raw raw no CAL raw files
P...
CAL product quality:
products products products products products products no CAL products
 
transfer   ngas [?]

scores&comments | FULL | history ... | plot tutorial ... | contact | HC_docu... | quality events...               [?]
*Date on this monitor changes at 21:00 UT
png: Information and research:
- png file - advanced studies: QC1 browser | QC1 plotter
Plot
?
Symb
?
Source
*
Average ? Thresholds ? N_
data
QC1
parameter
Data
downloads
Remarks
method value unit method value
1 QC1DB MEDIAN -0.398 ADU/pix/hr VAL-1.35,0.69 14 current_dark this | last_yr | all dark current, readout mode 225kHz,1x1,low; BLUE CCD
2 QC1DB MEDIAN 0.592 ADU/pix/hr VAL-0.382,1.394 15 current_dark this | last_yr | all same for REDU CCD
3 QC1DB MEDIAN 0.182   VAL-1.179,1.179 15 current_dark this | last_yr | all same for REDL CCD
4 QC1DB MEDIAN -1.21 ADU/pix/hr VAL-2.889,1.083 19 current_dark this | last_yr | all dark current, readout mode 50kHz,2x2,high; BLUE CCD
5 QC1DB MEDIAN 2.88 ADU/pix/hr VAL1.073,4.667 20 current_dark this | last_yr | all same for REDU CCD
6 QC1DB MEDIAN 1.09 ADU/pix/hr VAL-2.221,3.755 20 current_dark this | last_yr | all same for REDL CCD
*Data sources: QC1DB: QC1 database; LOCAL: local data source
Plot 1
scores: 3|
data source:uves_dark
(QC1 database)
dataset:current_dark
median:-0.398ADU/pix/hr
fixed thresholds:-1.35...0.69ADU/pix/hr
N_data plotted:14
[click plot for closeup]
Plot 2
scores: 3|
data source:uves_dark
(QC1 database)
dataset:current_dark
median:0.592ADU/pix/hr
fixed thresholds:-0.382...1.394ADU/pix/hr
N_data plotted:15
[click plot for closeup]
Plot 3
scores: 3|
data source:uves_dark
(QC1 database)
dataset:current_dark
median:0.182 
fixed thresholds:-1.179...1.179 
N_data plotted:15
[click plot for closeup]
Plot 4
scores: 3|
data source:uves_dark
(QC1 database)
dataset:current_dark
median:-1.21ADU/pix/hr
fixed thresholds:-2.889...1.083ADU/pix/hr
N_data plotted:19
[click plot for closeup]
Plot 5
scores: 3|
data source:uves_dark
(QC1 database)
dataset:current_dark
median:2.88ADU/pix/hr
fixed thresholds:1.073...4.667ADU/pix/hr
N_data plotted:20
[click plot for closeup]
Plot 6
scores: 3|
data source:uves_dark
(QC1 database)
dataset:current_dark
median:1.09ADU/pix/hr
fixed thresholds:-2.221...3.755ADU/pix/hr
N_data plotted:20
[click plot for closeup]
This plot

This is the trending report for UVES QC parameters derived from DARK frames.
These frames are taken approximately once per month, as a set of 3 consecutive exposures of 3600 secs each. These data are de-biased and combined into a MASTER_DARK, in which the average dark level is measured (in ADU/px/hr).
These plots describe:

  1. the DARK current in master DARK frames of the BLUE chip in the 1x1 binning, 225kHz, low gain readout mode
  2. same for REDL chip, 1x1
  3. same for REDU chip, 1x1
  4. the DARK current in master DARK frames of the BLUE chip in the 2x2 binning, 50kHz, high gain readout mode
  5. same for REDL chip, 2x2
  6. same for REDU chip, 2x2
From user manuals in e-/pix/h (ADU/pix/h) at -120C:
  1. BLUE Chip: 0.4 (lg: 0.22, hg: 0.74)
  2. RED CHIPL: 0.5 (lg: 0.31, hg: 0.96)
  3. RED CHIPU: 1.5 (lg: 1.03, hg: 2.88)
Thresholds and reference values are set using the KPI document
  1. BLUE_1x1_225 VAL=-1.35,0.69 REF=-0.33
  2. REDL_1x1_225 VAL=-0.382,1.394 REF=0.506
  3. REDU_1x1_225 VAL=-1.179,1.179 REF=0
  4. BLUE_2x2_50 VAL=-2.889,1.083 REF=-0.903
  5. REDL_2x2_50 VAL=1.073,4.667 REF=2.87
  6. REDU_2x2_50 VAL=-2.221,3.755 REF=0.767

Find more information about UVES DARK frames here.
You can see here basic QC parameters related to detector properties (like median level, ReadOut Noise, etc).  
General information

Click on any of the plots to see a close-up version.

The latest date is indicated on top of the plot.

If configured,

  • data points belonging to the latest date are specially marked
  • statistical averages are indicated by a solid line, and thresholds by broken lines
  • outliers are marked by a red asterisk. They are defined as data points outside the threshold lines
  • "aliens" (= data points outside the plot Y limits) are marked by a red arrow ( or )
  • you can download the data for each parameter set if the 'Data downloads' link shows up