GIRAFFE trending system: KPI report
HELP USERS-GUIDE MORE
Last update: 2025-12-18T16:42:01 (UT)
  | now: 2025-12-18T17:54:01 (UT) muc02 QC pipeline: giraf-2.16.14 (installed 2024-10-16)
General news: NOTE: The Health Check and calChecker services are moved to qcFlow on an instrument by instrument basis. The current pages will not be updated any longer once the move has been finished.
GIRAFFE news:  
Report news:

scores&comments | history: all data plotted here | plot tutorial ... | contact | HC_docu... | quality events...               [?]
*Date on this monitor changes at 21:00 UT
png: Information and research:
- png file - advanced studies: QC1 browser | QC1 plotter
Plot
?
Symb
?
Source
*
Average ? Thresholds ? N_
data
QC1
parameter
Data
downloads
Remarks
method value unit method value
1 QC1DB none   fraction none  194 mean_effic all (full time range) Efficiency at central wavelength (Argus, HR grating)
H447.1A
2 QC1DB none   fraction none  199 mean_effic all (full time range) H651.5B
3 QC1DB none   fraction none  185 mean_effic all (full time range) H875.7 (unreliable, no reference value possible)

4 QC1DB none   fraction none  225 mean_effic all (full time range) Argus, LR grating
L427.2
5 QC1DB none   fraction none  217 mean_effic all (full time range) L543.1
6 QC1DB none   fraction none  237 mean_effic all (full time range) L881.7 (unreliable, no reference value possible)
*Data sources: QC1DB: QC1 database; LOCAL: local data source
Plot 1
data source:giraffe_std
(QC1 database)
dataset:mean_effic
average:none
thresholds:none
N_data plotted:194
(current) reference:0.042
[click plot for closeup]
Plot 2
data source:giraffe_std
(QC1 database)
dataset:mean_effic
average:none
thresholds:none
N_data plotted:199
(current) reference:0.045
[click plot for closeup]
Plot 3
data source:giraffe_std
(QC1 database)
dataset:mean_effic
average:none
thresholds:none
N_data plotted:185
(current) reference:undefined
[click plot for closeup]
Plot 4
data source:giraffe_std
(QC1 database)
dataset:mean_effic
average:none
thresholds:none
N_data plotted:225
(current) reference:0.048
[click plot for closeup]
Plot 5
data source:giraffe_std
(QC1 database)
dataset:mean_effic
average:none
thresholds:none
N_data plotted:217
(current) reference:0.060
[click plot for closeup]
Plot 6
data source:giraffe_std
(QC1 database)
dataset:mean_effic
average:none
thresholds:none
N_data plotted:237
(current) reference:undefined
[click plot for closeup]
This plot

This is the instrument performance plot for the system efficiency of GIRAFFE. It is based on measurements of a flux standard star with the Argus IFU under photometric conditions. There are three settings taken with the low-resolution grating (L427.2, L543.1, L881.7) and three more with the high-resolution grating (H447.1A, H651.5B, H875.7). These data are taken approximately every month.

They are calibrated with the robotic lamp flats. The flats are used only for the localization solution (required for the extraction). Contrary to the usual reduction, the extracted flat-field is not divided into the standard star spectrum, in order not to corrupt the efficiency calculation.

We display the QC1 parameter mean_effic which is the ratio of detected photons and the incident photons. The signal from all fibres (excluding SKY and SIMCAL) is combined and averaged.

For comparison we also plot the current ETC values at the central wavelength of the setting. Check out the ETC for more.

The reference values are defined as best-performance values. The efficiency is expected to degrade over time, mainly because of the degrading coating of the gratings. The HR grating has been recoated in 2011-06, the effect is visible in plots #1 and #2. Efficiency drops by about -0.0033 per year in H447.1A and in H651.5B. We felt unable to determine a reference value for the two red settings in plots #3 and #6, where the measurement method is particularly bad presumably due to insufficient sky subtraction in the data.  


General information

Click on any of the plots to see a close-up version.

The latest date is indicated on top of the plot.

If configured,

  • data points belonging to the latest date are specially marked
  • statistical averages are indicated by a solid line, and thresholds by broken lines
  • outliers are marked by a red asterisk. They are defined as data points outside the threshold lines
  • "aliens" (= data points outside the plot Y limits) are marked by a red arrow ( or )
  • you can download the data for each parameter set if the 'Data downloads' link shows up