mirror sites: PL HQ

Health Check monitor

 

CAL | HC | refs | QC
HealthCheck Monitor
   HOME | UsersGuide
  sl icon ALL INSTRUMENTS
UVES:
gratings: position
Other HC:
QC links:
        [page auto-refreshes after 300 sec]   [stop | on]            [press Ctrl+R to enforce refresh of scores and dates]
UVES trending system: HEALTH CHECK report
Last update: 2012-05-26T06:26:18 (UT)
| now: 2012-05-26T07:48:52 (UT)
HELP USERS-GUIDE MORE
same group: 520_Plate1 580_P1 860_P1   520_Plate2 580_P2 860_P2
General news: 2012-05-24: The HC monitors for OMEGACAM, VIRCAM and HAWKI are back. Population with current data is in progress.
UVES news:  
Report news:  
DATE*: [?] 2012-05-19
report | NR
2012-05-20
report | NR
2012-05-21
report | NR
2012-05-22
report | NR
2012-05-23
report | NR
2012-05-24
report | NR
2012-05-25
report | NR
P...
Product quality:
products products products products products products products
  last OPSLOG data:
2012-04-30*

last files ...
monitor

scores&comments | history ... | plot tutorial ... | contact               [?]
*Date on this monitor changes at 21:00 UT
Print: Information and research:
- png file - advanced studies: QC1 browser | QC1 plotter
Plot
?
Symb
?
Source
*
OPS?
**
Average ? Thresholds ? N_
data
QC1
parameter
Data
downloads
Remarks
method value unit method value
1 QC1DB yes (0) MEDIAN -1.519 pixels OFF± 1.5 3 mean_dx this | last_yr | all DeltaX between solution and Physical Model, from MOS FMTCHK data, 860.0nm, 1x1, Plate 2, RED UPPER CCD
2 QC1DB yes (0) MEDIAN 2.158 pixels OFF± 1.5 3 mean_dy this | last_yr | all DeltaY, same data set
3 QC1DB yes (0) MEDIAN 174.0 pixels VAL160,250 3 nlin_sel this | last_yr | all Number of lines used in the solution, same data set

4 QC1DB yes (0) MEDIAN -0.68 pixels OFF± 1.5 3 mean_dx this | last_yr | all DeltaX between solution and physical model, 860.0nm, 1x1, Plate 2, RED LOWER CCD
5 QC1DB yes (0) MEDIAN 0.68 pixels OFF± 1.5 3 mean_dy this | last_yr | all DeltaY, same data set
6 QC1DB yes (0) MEDIAN 315.0 pixels VAL240,500 3 nlin_sel this | last_yr | all Number of lines used in the solution, same data set
*Data sources: QC1DB: QC1 database; LOCAL: local text file | **OPS: to indicate that OPSLOG data are included
Plot 1
scores: not implemented
data source:uves_fib_fmtchk
(QC1 database)
dataset:mean_dx
median:-1.519pixels
rel. thresholds: -3.019...-0.019pixels
N_data plotted:3
[click on plot for closeup]
Plot 2
scores: not implemented
data source:uves_fib_fmtchk
(QC1 database)
dataset:mean_dy
median:2.158pixels
rel. thresholds: 0.658...3.658pixels
N_data plotted:3
[click on plot for closeup]
Plot 3
scores: not implemented
data source:uves_fib_fmtchk
(QC1 database)
dataset:nlin_sel
median:174.0pixels
fixed thresholds:160.0...250.0pixels
N_data plotted:3
[click on plot for closeup]
Plot 4
scores: not implemented
data source:uves_fib_fmtchk
(QC1 database)
dataset:mean_dx
median:-0.68pixels
rel. thresholds: -2.18...0.82pixels
N_data plotted:3
[click on plot for closeup]
Plot 5
scores: not implemented
data source:uves_fib_fmtchk
(QC1 database)
dataset:mean_dy
median:0.68pixels
rel. thresholds: -0.82...2.18pixels
N_data plotted:3
[click on plot for closeup]
Plot 6
scores: not implemented
data source:uves_fib_fmtchk
(QC1 database)
dataset:nlin_sel
median:315.0pixels
fixed thresholds:240.0...500.0pixels
N_data plotted:3
[click on plot for closeup]
This plot

This is the trending report for the grating stability in FLAMES/UVES, derived from the MOS format check calibrations taken with wavelength setting 860, 1x1 binning and Plate 2. These data are only rarely taken and plotted here for completeness. They are not scored to avoid redundancy with the plate 1 plot.

Find more information in the description of the corresponding plot for plate 1.

Find more information about FLAMES/UVES Grating Position monitoring here.  


General information

Click on any of the plots to see a close-up version.

If applicable, the latest values from Paranal ops logs are plotted as blue dots. More information about those values, including a download option, is available in the OPS column.

The latest date is indicated on top of the plot, data points belonging to that date are specially marked.

If configured,

  • statistical averages are indicated by a solid line, and thresholds by broken lines
  • outliers are marked by a red asterisk. They are defined as data points outside the threshold lines
  • "aliens" (= data points outside the plot Y limits) are marked by a red arrow ( or )
  • you can download the data for each parameter set if the 'Data downloads' link shows up