mirror sites: PL (internal link) HQ     [?]

Health Check monitor

 

CAL | HC | refs | QC
HealthCheck Monitor
   HOME | UsersGuide
  sl icon ALL INSTRUMENTS
 
FULL reports
UVES:
   same (580 REDL)
Other HC:
QC links:
        [page auto-refreshes after 300 sec]   [stop | on]            [press Ctrl+Shift+R to enforce refresh of scores, dates and news]
UVES trending system: HEALTH CHECK report
HELP USERS-GUIDE MORE
Last update: 2014-10-24T16:06:12 (UT)
  | now: 2014-10-24T18:51:13 (UT) muc02 QC pipeline: uves-5.4.0 (installed 2014-10-20)
same group: FF_LAMP3 ThAr_LAMP1
General news:
UVES news:
Report news:
DATE*: [?] 2014-10-17
report | NLT
2014-10-18
report | NLT
2014-10-19
report | NLT
2014-10-20
report | NLT
2014-10-21
report | NLT
2014-10-22
report | NLT
2014-10-23
report | NLT
P...
Product quality:
products products products products products products products
  no OPSLOG data  

scores&comments | FULL | history ... | plot tutorial ... | contact                 daily/often; important to check     [?]
*Date on this monitor changes at 21:00 UT
Print: Information and research:
- png file - advanced studies: QC1 browser | QC1 plotter
Note that due to a bug in the recipe, data points with long exposure times (>300 sec) systematically deviate from the ones with the standard exposure times and have been suppressed. This effect starts with 2011-01.
Plot
?
Symb
?
Source
*
OPS?
**
Average ? Thresholds ? N_
data
QC1
parameter
Data
downloads
Remarks
method value unit method value
1 QC1DB no MEDIAN 0.115 counts/sec none  99 fib_effic_rel this | last_yr | all Flux of FLAMES/UVES SIMCAL lamp in counts/sec, from 580.0nm, 1x1, Plate 1 data, REDL CCD, in fibre 1
2 +QC1DB no none   counts/sec none  99 fib_effic_rel this | last_yr | all fibre 2, no filter
2 QC1DB no MEDIAN 0.122 counts/sec none  84 fib_effic_rel this | last_yr | all Flux of FLAMES/UVES robotic calibration lamp for flats. Same data as plot 1, fibre 2 (filtered for values <=0.14)
3 QC1DB no MEDIAN 0.125 counts/sec none  84 fib_effic_rel this | last_yr | all fibre 3
4 QC1DB no MEDIAN 0.141 counts/sec 20%± 0.0282 99 fib_effic_rel this | last_yr | all fibre 4

5 +QC1DB no none   counts/sec none  99 fib_effic_rel this | last_yr | all fibre 5, no filter
5 QC1DB no MEDIAN 0.148 counts/sec 20%± 0.0296 84 fib_effic_rel this | last_yr | all fibre 5 (filtered for values >=0.12)
6 +QC1DB no none   counts/sec none  99 fib_effic_rel this | last_yr | all fibre 6, no filter
6 QC1DB no MEDIAN 0.119 counts/sec none  84 fib_effic_rel this | last_yr | all fibre 6 (filtered for values >=0.10)
7 +QC1DB no none   counts/sec none  99 fib_effic_rel this | last_yr | all fibre 7, no filter
7 QC1DB no MEDIAN 0.0928 counts/sec none  86 fib_effic_rel this | last_yr | all fibre 7 (filtered for values >=0.07)
8 +QC1DB no none   counts/sec none  99 fib_effic_rel this | last_yr | all fibre 8, no filter
8 QC1DB no MEDIAN 0.137 counts/sec none  84 fib_effic_rel this | last_yr | all fibre 8 (filtered for values >=0.10)
*Data sources: QC1DB: QC1 database; LOCAL: local text file | **OPS: OPSLOG data are included
Plot 1
scores: not implemented
data source:uves_fib_fflat
(QC1 database)
dataset:fib_effic_rel
median:0.115counts/sec
thresholds:none 
N_data plotted:99
[click on plot for closeup]
Plot 2
scores: not implemented
data source:uves_fib_fflat
(QC1 database)
dataset:
(numbers below apply to this dataset)
fib_effic_rel+
average:none
thresholds:none
N_data plotted:99
[click on plot for closeup]
Plot 3
scores: not implemented
data source:uves_fib_fflat
(QC1 database)
dataset:fib_effic_rel
median:0.125counts/sec
thresholds:none 
N_data plotted:84
[click on plot for closeup]
Plot 4
scores: not implemented
data source:uves_fib_fflat
(QC1 database)
dataset:fib_effic_rel
median:0.141counts/sec
rel. thresholds: ±20%0.1128...0.1692counts/sec
N_data plotted:99
[click on plot for closeup]
Plot 5
scores: not implemented
data source:uves_fib_fflat
(QC1 database)
dataset:
(numbers below apply to this dataset)
fib_effic_rel+
average:none
thresholds:none
N_data plotted:99
[click on plot for closeup]
Plot 6
scores: not implemented
data source:uves_fib_fflat
(QC1 database)
dataset:
(numbers below apply to this dataset)
fib_effic_rel+
average:none
thresholds:none
N_data plotted:99
[click on plot for closeup]
Plot 7
scores: not implemented
data source:uves_fib_fflat
(QC1 database)
dataset:
(numbers below apply to this dataset)
fib_effic_rel+
average:none
thresholds:none
N_data plotted:99
[click on plot for closeup]
Plot 8
scores: not implemented
data source:uves_fib_fflat
(QC1 database)
dataset:
(numbers below apply to this dataset)
fib_effic_rel+
average:none
thresholds:none
N_data plotted:99
[click on plot for closeup]
This plot

This is the trending report for the FLAMES/UVES fibre flat lamps. It is based on data taken with the RED LOWER CCD in setting 580, 7+1FIB, with Plate 1. These data are taken daily as part of the Health Checks. Note: there are no such data in the opslog files.

Note this is a trending plot only, no scores are evaluated. For Health Checks, we also display data taken with the RED UPPER CCD, see here.

Two lamps are monitored here: the SIMCAL lamp for the simultaneous calibrations (in fibre 1), and the regular flat field lamp LAMP3. Trends in this plot probably indicate aging of the lamps. The lamp is used for fibre flat and order definition calibrations.

The plots also monitor trends in the throughput of the fibres: if all but one fibre show a signal from the lamp, a fibre with low or no signal has clearly a problem.

The individual plots describe:

  • Fibre 1: the flux reported by the pipeline as QC.FIB1.RELTRANS in the products.
    This fibre 1 is illuminated by the simultaneous calibration Tungsten lamp.
  • Fibres 2-8: the overall flux reported by the pipeline as QC.FIB[2-8].RELTRANS in the products.
    These fibres are illuminated by the robotic fibre projector fed by a Tungsten lamp.

The same trending for the UPPER chip is here. [The scores of that report do contribute to the "score overview".]
Find more information about FLAMES/UVES Lamp monitoring here.  
General information

Click on any of the plots to see a close-up version. The latest date is indicated on top of the plot, data points belonging to that date are specially marked.

If configured,

  • statistical averages are indicated by a solid line, and thresholds by broken lines
  • outliers are marked by a red asterisk. They are defined as data points outside the threshold lines
  • "aliens" (= data points outside the plot Y limits) are marked by a red arrow ( or )
  • you can download the data for each parameter set if the 'Data downloads' link shows up