VIRCAM trending system: HEALTH CHECK plot
Last update: 2009-11-21T22:05:58 (UT)
| now: 2009-11-21T22:13:37 (UT)
HELP USERS-GUIDE MORE
same group: MED_1.0011 RON12_1.0011 RMS_1.0011 STRIPE_1.0011   MED_120 RON12_120 RMS_120 STRIPE_120
last OPSLOG data:
2009-11-19
Plot: 1 2 3 4   latest_files
N_data: number of recent OPSLOG entries plotted here
N_data: 17 272 17 - availability
scores ... | history ... | plot tutorial ... | contact                 daily/often; important to check     [?]
Print: Information and research: News:
- png file - advanced studies: QC1 browser | QC1 plotter
  • REFERENCE frames
  • 2009-06-03: Scoring (red/green squares in the group bar and in the navigation bar) is on the detector average (Fig. 1) and detector rms (Fig. 3) values alone.
    Scores of individual detector values (Fig. 4) are for detailed analysis but do not contribute to the overall instrument score.
  • 2009-10-27 dailty dark setups: DIT = 1.0011, 120 sec.
Plot
?
Symb
?
Source
*
OPS?
**
Average ? Thresholds ? N_
data
QC1
parameter
Data
downloads
Remarks
method value unit method value
1 QC1DB yes (17) MEDIAN -0.05536 ADU VAL-1,2 52 qc_darkmed this | last_yr | all DARKMED, average over all 16 detectors
2 QC1DB yes (272) MEDIAN -0.08789 ADU VAL-1,2 811 qc_darkmed this | last_yr | all DARKMED, values of all detetcors
3 QC1DB yes (17) MEDIAN 0.31894 ADU VAL-1,2 52 qc_darkmed this | last_yr | all DARKMED, stdev over all detectors
4 [19]LOCAL no none   ADU none   816 qc_darkmed n/a Score per Detector: Green = within the thresholds
4 [19]LOCAL no none   ADU none   16 qc_darkmed n/a Score per Detector: Red = beyond thresholds
4 +LOCAL no none   ADU none   816 qc_darkmed n/a Score per Detector: Green = within the thresholds
4 LOCAL no none   ADU none   16 qc_darkmed n/a Score per Detector: Red = beyond thresholds
*Data sources: QC1DB: QC1 database; LOCAL: local text file | **OPS: to indicate that OPSLOG data are included
This plot

Trending plot for median dark level.

QC parameters is derived from each detector of daily DARK frames.

Name:
Fits header: QC.DARKMED,
QC1 DB: qc_darkmed

Description:
Median of the MASTER_DARK pipeline product frame

Setup:
DET.DIT = 1.0011 sec

DET.NDIT = 1

These plots describe:
Fig. 1. Average view: The QC parameter averaged over all detectors. This view is sensitive to common changes.
Fig. 2. Resolved View: The QC parameter resolved for all detectors.
Fig. 3. Scatter View: The standard deviation of the QC parameter, obtained from the sample of all detectors. This view is sensitive changes of individual detectors.
Fig. 4. Scoring View: Scoring values of all 16 QC parameters. Green = within the acceptance thresholds. Red = beyond the acceptance thresholds.

Find more information on the VIRCAM DARK tutorial page.

 


General information

Click on any of the plots to see a close-up version.

If applicable, the latest values from Paranal ops logs are plotted as blue dots. More information about those values, including a download option, is available in the OPS column.

The latest date is indicated on top of the plot, data points belonging to that date are specially marked.

If configured,

  • statistical averages are indicated by a solid line, and thresholds by broken lines
  • outliers are marked by a red asterisk. They are defined as data points outside the threshold lines
  • "aliens" (= data points outside the plot Y limits) are marked by a red arrow ( or )
  • you can download the data for each parameter set if the 'Data downloads' link shows up