mirror sites: PL (internal link) HQ     [?]

Calibration completeness monitor

 

[all links are internal]             [page auto-refreshes after 300 sec]   [stop | on]            [press Ctrl+Shift+R to enforce refresh of "ago" time information]
CAL | HC | refs | QC
CALCHECKER
  HOME | HELP
  sl icon ALL INSTRUMENTS
VISIR
QC links:
CAL
VISIR calChecker: calibration completeness monitor
Last update: 2017-06-24T14:55:37 (UT)
[?]
  Paranal date*: 2017-06-23         muc03 [?]   server: www.eso.org HQ
HELP ASSOC-RULES DETAILS
Last header: VISIR. 2017-06-24T10:49:00.628.hdr
transfer     ngas    [?]
  *Date on this monitor changes at 21:00 UT. Refresh frequency: 1/2hr day and night
General news:
Long-term calibrations: none defined
VISIR news:

       

HELP | Q&A | ASSOC-RULES   history... | contact   monitors: DataTransferMonitor | BandWidth
  science   no cal4cal   tellTracker   [?]     Product availability depends on the data transfer to Garching and the archive access there (check the "transfer" and "ngas" flags above).
  daytime calibs:   pending
DATE*:   [?]
[color if science data acquired]
2017-06-17

report | NLT
2017-06-18
VM
416
report | NLT
2017-06-19

report | NLT
2017-06-20
SM
100
report | NLT
2017-06-21

report | NLT
2017-06-22
SM
41
report | NLT
2017-06-23
SM
120
report | NLT
LOST?
[may require OB
grade review]
Calibration action?     [?]
[take these data types ...
Setup:
... for these setups]
r...
Raw CAL displays:     [?]
raw raw raw raw raw raw raw      
P...
Product quality:     [?]
products products products products products products products      
Data types: Setup:        
SCI_IMG_CHNJ Q1_0.0453  
 
 
ok
 
 
 
  all ok  
SCI_IMG_CHNB J7.9_0.0453  
 
 
ok
 
 
 
  all ok  
SCI_SPEC_CHN 0.400_OPEN  
ok
analyzed: [1]
 
 
 
ok
ok
  all ok  
0.750_OPEN  
ok
analyzed: [2]
 
ok
 
 
 
  all ok  
1.000_OPEN  
ok
analyzed: [3]
 
 
 
 
 
  all ok  
ANALYSIS NOTES:
Index data type setup date flag analysis
[1]SCI_SPEC_CHN0.400_OPEN2017-06-18OKscience OB in visitor mode, supposedly OK (analyzed by scerda@eso.org)
[2]SCI_SPEC_CHN0.750_OPEN2017-06-18OKscience OB in visitor mode, supposedly OK (analyzed by scerda@eso.org)
[3]SCI_SPEC_CHN1.000_OPEN2017-06-18OKscience OB in visitor mode, supposedly OK (analyzed by scerda@eso.org)
 
INFORMATION SPECIFIC TO VISIR           [?]
The following keys are used to define a SCIENCE VISIR setup:
imaging:ins.filt1.name, ins.pfov
spectroscopy:ins.slit1.wid, ins.filt2.name

The following checks are performed:
imaging standard stars should be taken within +/- 3 hr from the science observations
telluric standard stars should be taken within +/- 2 hr and within the airmass difference of 0.2 from the science observation.
standard stars for coronography (SCI_CORO) and echelle (SCI_SPEC_ECH) are only observed if the PI provides the required OBs.
CONFIGURATION           [?]
Number of days scanned: 7
Range of days for the issue memory (configured): 20
Range of days for the calibration memory (issue memory plus longest validity): 20
Days in the calibration&issue memory:
*Date on this monitor changes at: 21:00 UT
powered by QC [calChecker v4.6.2]   increm