mirror sites: PL (internal link) HQ     [?]

Health Check monitor

 

CAL | HC | refs | QC
HealthCheck Monitor
   HOME | UsersGuide
  sl icon ALL INSTRUMENTS
 
all KPI reports
XSHOOTER:
wavelength calib.
Other HC:
QC links:
        [page auto-refreshes after 300 sec]   [stop | on]            [press Ctrl+Shift+R to enforce refresh of scores, dates and news]
XSHOOTER trending system: HEALTH CHECK report
HELP USERS-GUIDE MORE
Last update: 2024-03-18T22:38:34 (UT)
  | now: 2024-03-19T11:56:14 (UT) muc02 QC pipeline: xshoo-3.6.5a (installed 2023-09-18)
same group: wavecal_slit wave_slit_time wave_ifu_time
General news: NOTE: The Health Check and calChecker services are moved to qcFlow on an instrument by instrument basis. The current pages will not be updated any longer once the move has been finished.
XSHOOTER news:  
Report news:
DATE*: [?] 2024-03-12
report | NLT
2024-03-13
report | NLT
2024-03-14
report | NLT
2024-03-15
report | NLT
2024-03-16
report | NLT
2024-03-17
report | NLT
2024-03-18
report | NLT
r...
Raw CAL displays:
raw raw raw raw raw raw raw
P...
CAL product quality:
products products products products products products products
 
transfer   ngas [?]

scores&comments | history ... | plot tutorial ... | contact | HC_docu... | quality events...                 daily/often; important to check     [?]
*Date on this monitor changes at 21:00 UT
png: Information and research:
- png file - advanced studies: QC1 browser | QC1 plotter
Plot
?
Symb
?
Source
*
Average ? Thresholds ? N_
data
QC1
parameter
Data
downloads
Remarks
method value unit method value
1 QC1DB none   NONE none  78 nline_found this | last_yr | all number of lines identified
2 QC1DB none   NONE none  78 resol_med this | last_yr | all median resolution (bad lines clipped) 1x1 binning and plynomial fit
3 QC1DB none   NONE none  78 model_diffy_med this | last_yr | all median difference in y between 9-pinhole and slit data
4 QC1DB none   NONE none  78 model_diffy_rms this | last_yr | all rms of difference in y between 9-pinhole and slit data
*Data sources: QC1DB: QC1 database; LOCAL: local data source
Plot 1
scores: not implemented
data source:xshooter_wavecal
(QC1 database)
dataset:nline_found
average:none
thresholds:none
N_data plotted:78
[click plot for closeup]
Plot 2
scores: not implemented
data source:xshooter_wavecal
(QC1 database)
dataset:resol_med
average:none
thresholds:none
N_data plotted:78
[click plot for closeup]
Plot 3
scores: not implemented
data source:xshooter_wavecal
(QC1 database)
dataset:model_diffy_med
average:none
thresholds:none
N_data plotted:78
[click plot for closeup]
Plot 4
scores: not implemented
data source:xshooter_wavecal
(QC1 database)
dataset:model_diffy_rms
average:none
thresholds:none
N_data plotted:78
[click plot for closeup]
This plot

These plots show information derived from arc observations with a slit vs. the slit width.

The change in spectral resolution is caused by using a more suitable value for one of the arc recipe command line parameters since 2017-12. Details are given in the history section of the plot tutorial.

New 2019-02:

UVB
Resolving power top level requirement (TLR) derived from design specification for UVB-arm is lam/dlam = 5000 at 1.0 arcsec slit width. Observed values for 2017-10...2019-02 calibrations show 5440+-14. Polynomial fit (slit^3) covering 2019-01 and slits 0.4x11 ... 1.6x11 shows: 5390 at 1.0''. Scaling the best-fit polynomial, by 5000/5390 (=0.938) results in the TLR for any slit (dashed line).

VIS
resolving power TLR for VIS arm is lam/dlam = 7500 at 1.0 arcsec slit width. Observed values for 1.0'' are not available. Ploynomial fit (see Box 2) shows 7880 at 1.0 arcsec. Scaling the best-fit polynomial, by 7500/7880 (=0.952) results in the TLR for any slit (dashed line).

UVB
resolving power top level requirement for VIS arm is 4800 at 1.0 arcsec slit width. Ploynomial fit (see Box 2) shows 5120 at 1.0 arcsec. Scaling the best-fit polynomial, by 4800/5120 (=0.938) results in the TLR for any slit (dashed line).

For more information see the plot tutorial page.  


General information

Click on any of the plots to see a close-up version.

The latest date is indicated on top of the plot.

If configured,

  • data points belonging to the latest date are specially marked
  • statistical averages are indicated by a solid line, and thresholds by broken lines
  • outliers are marked by a red asterisk. They are defined as data points outside the threshold lines
  • "aliens" (= data points outside the plot Y limits) are marked by a red arrow ( or )
  • you can download the data for each parameter set if the 'Data downloads' link shows up