| This documentation is intended both for QC scientists and SciOps astronomers (who may want to ignore the technical information displayed in grey).
|
| |
|
|
|
|
| |
|
bottom
plots
|
contact
|
|
| NAME |
qc_DARK_SPEC.sh
|
|
| VERSION |
1.0 -- created (2006-12-15)
|
|
| SYNTAX |
SHELL
|
|
| CALL |
processQC
from $DFS_PRODUCT/DARK_SPEC/$DATE:
qc_DARK_SPEC.sh $date $primfile
|
|
| INSTRUMENT |
VISIR
|
|
| RAWTYPE |
DARK_SPEC
|
|
| PURPOSE |
extracts QC parameters and records them in the local qclog table $DFO_TREND_DIR/DARK_SPEC.qclog
|
|
| PROCINPUT |
dark product of the spctroscopic detector
|
|
| QC1TABLE |
trending | table(s) in QC1 database:
visir_dark_spc
|
|
| TRENDPLOT |
trending | HealthCheck plot(s) associated to this procedure:
trend_report_RON_HC.html |
trend_report_DARK_HC.html
|
|
| QC1PAGE |
trending | associated documentation:
dark_qc1.html
|
|
QC1PLOTS
top |
|
|
| QC1PARAM |
QC1 parameters written into local QC1 table $DFO_TREND_DIR/DARK_SPEC.qclog:
QC.RON1, QC.DARKMED, QC.NBCOLPIX, QC.NBHOTPIX, QC.NBDEVPIX
FITS key names: DET.DIT | DET.NDIT | INS.FILT2.NAME
QC1 params created by pipeline: all
QC1 params created by this procedure: none
|
|
| ALGORITHM |
Description of algorithms:
QC.RON1, QC.DARKMED, QC.NBCOLPIX, QC.NBHOTPIX, QC.NBDEVPIX : calculated as for NACO
|
|
| CERTIF |
Reasons for rejection: - NONE; product is not used for data calibration
|
|
| COMMENTS |
NONE
|
| top |
[2012-06-20T10:56:50] created by qcDocu v1.1.2, a tqs tool
|