SINFONI trending system: HEALTH CHECK report
HELP USERS-GUIDE MORE
Last update: 2017-03-26T12:29:35 (UT)
  | now: 2017-03-26T13:06:02 (UT) muc04 QC pipeline: sinfo-2.9.2 (installed 2016-12-20)
same group: slit_dist_ALL slit_dist_JHK distortion_shift   distortion_coef00 coef01 coef10 coef11 coef20 coef02 coef21
General news:
SINFONI news:
Report news:
DATE*: [?] 2017-03-19
report | NLT
2017-03-20
report | NLT
2017-03-21
report | NLT
2017-03-22
report | NLT
2017-03-23
report | NLT
2017-03-24
report | NLT
2017-03-25
report | NLT
r...
Raw CAL displays:
raw raw raw raw raw raw raw
P...
Product quality:
products products products products products products products
 
transfer   ngas [?]

scores&comments | history ... | plot tutorial ... | contact               [?]
*Date on this monitor changes at 21:00 UT
Print: Information and research:
- png file - advanced studies: QC1 browser | QC1 plotter
Plot
?
Symb
?
Source
*
Average ? Thresholds ? N_
data
QC1
parameter
Data
downloads
Remarks
method value unit method value
1 QC1DB MEDIAN -1.14 x10^-3_pixels^-1 OFF± 2 10 qc_coeff_01 this | last_yr | all J-band distortion coefficient C01 x 10^-3 (dist = C00 + C10x + C01y + C11xy + C20x^2 + C02y^2 + C21x^2y + C12xy^2)
2 QC1DB MEDIAN -2.36 x10^-3_pixels^-1 OFF± 2 13 qc_coeff_01 this | last_yr | all H-band distortion coefficient C01 x 10^-3
3 QC1DB MEDIAN -3.58 x10^-3_pixels^-1 OFF± 2 12 qc_coeff_01 this | last_yr | all K-band distortion coefficient C01 x 10^-3
4 QC1DB MEDIAN -6.19 x10^-3_pixels^-1 OFF± 2 14 qc_coeff_01 this | last_yr | all H+K-band distortion coefficient C01 x 10^-3
*Data sources: QC1DB: QC1 database; LOCAL: local data source
Plot 1
scores: 1|
data source:sinfoni_dist
(QC1 database)
dataset:qc_coeff_01
median:-1.14x10^-3_pixels^-1
rel. thresholds: -3.143...0.857x10^-3_pixels^-1
N_data plotted:10
[click on plot for closeup]
Plot 2
scores: 3|
data source:sinfoni_dist
(QC1 database)
dataset:qc_coeff_01
median:-2.36x10^-3_pixels^-1
rel. thresholds: -4.362...-0.362x10^-3_pixels^-1
N_data plotted:13
[click on plot for closeup]
Plot 3
scores: 5|
data source:sinfoni_dist
(QC1 database)
dataset:qc_coeff_01
median:-3.58x10^-3_pixels^-1
rel. thresholds: -5.5755...-1.5755x10^-3_pixels^-1
N_data plotted:12
[click on plot for closeup]
Plot 4
scores: 4|
data source:sinfoni_dist
(QC1 database)
dataset:qc_coeff_01
median:-6.19x10^-3_pixels^-1
rel. thresholds: -8.189...-4.189x10^-3_pixels^-1
N_data plotted:14
[click on plot for closeup]
This plot

These are the trending plots for the SINFONI QC parameters derived from DISTORTION frames.

Distortion frames are obtained for the J, H, K, and H+K bandpasses, but only for the 250 mas camera.

 


General information

Click on any of the plots to see a close-up version.

The latest date is indicated on top of the plot.

If configured,

  • data points belonging to the latest date are specially marked
  • statistical averages are indicated by a solid line, and thresholds by broken lines
  • outliers are marked by a red asterisk. They are defined as data points outside the threshold lines
  • "aliens" (= data points outside the plot Y limits) are marked by a red arrow ( or )
  • you can download the data for each parameter set if the 'Data downloads' link shows up