[page auto-refreshes after 300 sec]   [stop | on]            [press Ctrl+R to enforce refresh of scores and dates]
UVES trending system: HEALTH CHECK report
Last update: 2012-05-26T06:20:53 (UT)
| now: 2012-05-26T07:47:22 (UT)
HELP USERS-GUIDE MORE
same group: Resolution   Blue_A Blue_B RedU_A RedU_B RedL_A RedL_B
General news: 2012-05-24: The HC monitors for OMEGACAM, VIRCAM and HAWKI are back. Population with current data is in progress.
UVES news:  
Report news:
DATE*: [?] 2012-05-19
report | NR
2012-05-20
report | NR
2012-05-21
report | NR
2012-05-22
report | NR
2012-05-23
report | NR
2012-05-24
report | NR
2012-05-25
report | NR
P...
Product quality:
products products products products products products products
  no OPSLOG data  
close window history: 2007 2008 2009 2010 2011   2012   HEALTH
  ... ... ... ...
*Date on this monitor changes at 21:00 UT
Print: Information and research:
- png file - advanced studies: QC1 browser | QC1 plotter
Plot
?
Symb
?
Source
*
OPS?
**
Average ? Thresholds ? N_
data
QC1
parameter
Data
downloads
Remarks
method value unit method value
1 QC1DB no MEDIAN 113.28877 R VAL105.,125. 99 resol_med this | last_yr | all Average resolving power, from ARCLAMP data for REDL 580.0nm, 1x1, 0.3arcs slit
3 QC1DB no MEDIAN 1399.0 Number VAL1080,1500 99 nlin_tot this | last_yr | all Number of lines found, same data
4 QC1DB no MEDIAN 6.56559 R VAL5,11 99 resol_rms this | last_yr | all RMS of resolving power, same data
5 QC1DB no FIXED 65.0 Number OFF± 10.0 99 nlin_int this | last_yr | all Number of lines used in Integrated Average Intensity, same data
6 QC1DB no MEDIAN 616.0 Number VAL530,650 99 nlin_sol this | last_yr | all Number of lines actually used in final solution, same data
*Data sources: QC1DB: QC1 database; LOCAL: local text file | **OPS: to indicate that OPSLOG data are included
Plot 1
scores: 13|
data source:uves_wave
(QC1 database)
dataset:resol_med
median:113.28877R
fixed thresholds:105.0...125.0R
N_data plotted:99
[click on plot for closeup]
Plot 3
scores: 13|
data source:uves_wave
(QC1 database)
dataset:nlin_tot
median:1399.0Number
fixed thresholds:1080.0...1500.0Number
N_data plotted:99
[click on plot for closeup]
Plot 4
scores: not implemented
data source:uves_wave
(QC1 database)
dataset:resol_rms
median:6.56559R
fixed thresholds:5.0...11.0R
N_data plotted:99
[click on plot for closeup]
Plot 5
scores: 13|
data source:uves_wave
(QC1 database)
dataset:nlin_int
fixed average:65.0Number
rel. thresholds: 55.0...75.0Number
N_data plotted:99
[click on plot for closeup]
Plot 6
scores: 13|
data source:uves_wave
(QC1 database)
dataset:nlin_sol
median:616.0Number
fixed thresholds:530.0...650.0Number
N_data plotted:99
[click on plot for closeup]
This plot

This is the trending report for monitoring UVES Resolution based on QC parameters derived from Wavelength Calibration frames.
This report presents a second set of detailed parameters of the wavelength solution for the LOWER chip of the RED 580.0nm, 1x1 binning data, 4pts/625kHz/lg readout mode, 0.3 arcsec slit-width setup.
The individual plots describe:

  1. The average of the resolution values measured for each line included in the final selection, (this is a repeat of the data presented in the RESOLUTION overview report.
  2. The average of the intensity values measured for a subset of lines (taken from the LINE_INTMON_TABLE, if provided, in the sof, normally UV_GLIM_040226A_line_intmon_table.fits).
  3. The total number of lines found in the frame. The PL automatically adjusts the detection threshold until the number of lines found falls within the --minlines and --maxlines parameters of the recipe, by default 1100 and 1600 for the REDL chip
  4. The RMS of the resolution values measured for each line included in the final selection
  5. The number of lines included in the calculation of the average of the intensity
  6. The number of lines included in the final wavelength calibration solution. The selection is made in a two step process, first line with residuals larger than --tolerance (default 0.6 pix) are discarded, then the remaining list is further refined with kappa-sigma clipping controlled by the --kappa (default 4.0 sigma) recipe command line option.

Find more information about UVES Wavelength Solution monitoring here.  
General information

Click on any of the plots to see a close-up version. The latest date is indicated on top of the plot, data points belonging to that date are specially marked.

If configured,

  • statistical averages are indicated by a solid line, and thresholds by broken lines
  • outliers are marked by a red asterisk. They are defined as data points outside the threshold lines
  • "aliens" (= data points outside the plot Y limits) are marked by a red arrow ( or )
  • you can download the data for each parameter set if the 'Data downloads' link shows up