[page auto-refreshes after 300 sec]   [stop | on]            [press Ctrl+Shift+R to enforce refresh of scores, dates and news]
UVES trending system: HEALTH CHECK report
HELP USERS-GUIDE MORE
Last update: 2024-06-17T13:24:35 (UT)
  | now: 2024-06-17T14:03:59 (UT) muc02 QC pipeline: uves-6.1.11 (installed 2023-06-22)
same group: Resolution   B_CD2_A B_CD2_B RU_CD3_A RU_CD3_B RL_CD3_A RL_CD3_B Thermal FWHM
close window history: 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 2017 2018 2019 2020 2021 2022 2023   2024   HEALTH
  ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ...
*Date on this monitor changes at 21:00 UT
png: Information and research:
- png file - advanced studies: QC1 browser | QC1 plotter
Plot
?
Symb
?
Source
*
Average ? Thresholds ? N_
data
QC1
parameter
Data
downloads
Remarks
method value unit method value
1 QC1DB MEDIAN 5.82e+03 Angstrom VAL5818,5823 99 lambda_min this | last_yr | all Minimum wavelength in A, from ARCLAMP data for REDU 580.0nm, 1x1, 0.3arcs slit
2 QC1DB MEDIAN 90 Angstrom VAL90,91 98 order_min_det this | last_yr | all Minimum order number, same data
3 QC1DB MEDIAN 0 Angstrom VAL-0.0001,0.0001 98 resid_avg this | last_yr | all Average residual in A, same data
4 QC1DB MEDIAN 6.82e+03 Angstrom VAL6723.2,6834.9 98 lambda_max this | last_yr | all Maximum wavelength in A, same data
5 QC1DB MEDIAN 105 Angstrom VAL104,106 98 order_max_det this | last_yr | all Maximum order number, same data
6 QC1DB MEDIAN 0.798 milli-Angstrom VAL0,0.922 98 resid_rms this | last_yr | all RMS of residuals in mA, same data
*Data sources: QC1DB: QC1 database; LOCAL: local data source
Plot 1
scores: 8|
data source:uves_wave
(QC1 database)
dataset:lambda_min
median:5.82e+03Angstrom
fixed thresholds:5818...5823Angstrom
N_data plotted:99
[click plot for closeup]
Plot 2
scores: 8|
data source:uves_wave
(QC1 database)
dataset:order_min_det
median:90Angstrom
fixed thresholds:90...91Angstrom
N_data plotted:98
[click plot for closeup]
Plot 3
scores: 8|
data source:uves_wave
(QC1 database)
dataset:resid_avg
median:0Angstrom
fixed thresholds:-0.0001...0.0001Angstrom
N_data plotted:98
[click plot for closeup]
Plot 4
scores: 8|
data source:uves_wave
(QC1 database)
dataset:lambda_max
median:6.82e+03Angstrom
fixed thresholds:6723.2...6834.9Angstrom
N_data plotted:98
[click plot for closeup]
Plot 5
scores: 8|
data source:uves_wave
(QC1 database)
dataset:order_max_det
median:105Angstrom
fixed thresholds:104...106Angstrom
N_data plotted:98
[click plot for closeup]
Plot 6
scores: 8|
data source:uves_wave
(QC1 database)
dataset:resid_rms
median:0.798milli-Angstrom
fixed thresholds:0...0.922milli-Angstrom
N_data plotted:98
[click plot for closeup]
This plot

This is the trending report for monitoring UVES Resolution based on QC parameters derived from Wavelength Calibration frames.
This report presents a first set of detailed parameters of the wavelength solution for the UPPER chip of the RED 580.0nm, 1x1 binning data, 4pts/625kHz/lg readout mode, 0.3 arcsec slit-width setup.
The individual plots describe:

  1. the minimum wavelength of the solution, changes of a few nm usually occur because of changes in the last detected line, which often happens when the position of the orders changes slightly (see Grating Position trending). Changes of tens-hundreds of nm are usually due to the pipeline failing to locate entire orders
  2. the minimum order found in the solution. Previous to version 4.9.6 the PL only reported the minimum order expected. Minimum order found is available in the QC1 database only since 2011-05-05.
  3. The average of the residuals of the lines used in the final solution with respect to their laborotory wavelengths
  4. the maximum wavelength of the solution, changes of a few nm usually occur because of changes in the last detected line, which often happens when the position of the orders changes slightly (see Grating Position trending). Changes of tens-hundreds of nm are usually due to the pipeline failing to locate entire orders
  5. the maximum order found in the solution. Previous to version 4.9.6 the PL only reported the maximum order expected. Maximum order found is available in the QC1 database only since 2011-05-05
  6. the RMS of the residuals of the lines used in the final solution with respect to their laborotory wavelengths
Here we give the lambda min and max as well as the gap between the 2 CHIPs.

  • from User manual (WL_min/central_WL/WL_max/gap):
    # DIC1 CD1 303/346/388/na
    # DIC1 CD2 326/390/445/na
    # DIC1 CD3 458/564/668/2
    # DIC1 CD3 476/580/684/5
    # DIC2 CD1 303/346/388/na
    # DIC2 CD2 326/390/445/na
    # DIC1 CD3 476/580/684/5
    # DIC2 CD1 303/346/388/na
    # DIC2 CD2 326/390/445/na
    # DIC2 CD2 373/437/499/na
    # DIC2 CD4 565/760/946/7
    # DIC2 CD4 660/860/1060/10
    # blue CD1 303/346/388/na
    # blue CD2 373/437/499/na
    # red CD3 414/520/621/1
    # red CD3 476/580/684/5
    # red CD3 500/600/705/5
    # red CD4 660/860/1060/10
  • from ETC (WL_min_L/WL_max_L/central_WL/WL_min_U/WL_max_U):
    # 302/346/388
    # 326/390/452
    # 373/437/500
    # 414/521.37/520/521.6/621
    # 458/564.4/564/565.5/667
    # 473/580.36/580/581.82/683
    # 496/597.26/600/599.11/707
    # 575/747.15/760/766.07/946
    # 665/854.39/860/864.59/1060.57

    Find more information about UVES Wavelength Solution monitoring here.  


    General information

    Click on any of the plots to see a close-up version.

    The latest date is indicated on top of the plot.

    If configured,

    • data points belonging to the latest date are specially marked
    • statistical averages are indicated by a solid line, and thresholds by broken lines
    • outliers are marked by a red asterisk. They are defined as data points outside the threshold lines
    • "aliens" (= data points outside the plot Y limits) are marked by a red arrow ( or )
    • you can download the data for each parameter set if the 'Data downloads' link shows up