PIPELINE: GENERAL | The reduction of
SINFONI data at QC Garching is done in a semiautomatic manner: raw data are selected
and inserted into a reduction mechanism which produces This
mechanism is the SINFONI reduction pipeline. The SINFONI
pipeline consists of a number of recipes. They are based on the ESO common
pipeline library (CPL).
From here you can go to : |
![[top]](../img/arr1red-up.gif) | OPERATIONS |
| SINFONI pipeline |
| calibration |
|
| science
reduction | |
| recipes
calibration | |
| recipe science | ![[recipe science]](../img/ball_red.gif) |
| There are two different applications of
the SINFONI reduction pipeline:
- at the YEPUN telescope
(UT4) on Paranal, running in automatic mode,
- at HQ Garching run by the
Quality Control Team in the optimized mode.
The automatic operational
mode is used for quick look purposes and for on-site quality control. It processes
all raw data sequentially, i.e. as they arrive from the instrument. It produces
calibration products and reduced science data, but will usually not obtain the
best possible results. This is due to the sequential operation: post observation
daytime calibrations are not available during nighttime. The optimized
operational mode becomes possible when all data of a night including the associated
daytime calibrations have been collected. Then the calibration data are sorted
and assessed independently of their timestamp. The best possible master calibration
data are created. Their quality is checked. They are finally applied to the science
data of a night. This is the way all calibration data in supported modes are reduced
by QC Garching, as are all science data from Service Mode programs. |
![[top]](../img/arr1red-up.gif) |
SUPPORTED
MODES AND SETTINGS | |
|
The SINFONI pipeline presently supports all offered
modes, except DITHER mode.
QC Garching processes the following SINFONI
data - all pipeline supported calibration data taken with SINFONI no matter
whether Service or Visitor Mode. Calibrations taken for technical reasons (DPR.CATG
= TECHNICAL or TEST) are not processed.
- all science data taken in SINFONI
supported modes taken in Service Mode. Science data obtained with the GenericOffset
template is only processible under certain jitter offset constraints.
|
![[top]](../img/arr1red-up.gif) | FUNCTIONALITY'S |
|
| The
main functionalities of the SINFONI pipeline are:
- create
master calibration data,
- reduce science
frames,
- provide QC1 parameters.
QC
Garching creates - calibration
products from raw calibration data, both for Visitor Mode and Service
Mode nights. These raw data are stored in the ESO Archive and are public.
They are assessed and selected in terms of their quality and used for QC1 checks
and trending;
- reduced
science data for Service Mode nights. For SM programs, QC Garching
runs the pipeline on all science raw data taken in no-DITHER mode, using the best
available, quality-checked master calibration data. SPIDER mode is not supported.
Science stacks without embedded DPR.TYPE = SKY frames as generated by the AutoJitter
or GenericOffset template are reduced on a best effort basis.
|
![[top]](../img/arr1red-up.gif) | SERVICE
MODE PACKAGE |
SM
package |
Programs performed in Service Mode receive a set of DVDs which contains
- all raw science data,
- reduced science data,
-
suitable calibration data (both raw and master),
- listings and logs,
- QC1
reports.
- pipeline intermediate step products (e.g. individual science
cube without being co-added)
The following list shows the dates from
which on a new esorex/cpl version is used to reduce the data.
- 2004-10-01, esorex 0.4.8
- 2005-01-01, esorex 0.5.2
- 2005-02-16,
esorex 0.5.9 (for data of 2004-11-24 on)
- 2005-05-01, esorex 1.0.3 (for
data of 2005-03-13 on)
- 2005-05-13, esorex 1.0.4 (for data of ~ 2005-03-30
on)
- 2005-05-24 , esorex 1.0.5 (for science data of ~2005-04-05 on)
- 2005-06-17,
V 1.0.6 (for science of 2004-04-28 on, for calibrations of 2005-05-23 on)
- 2005-07-11,
V 1.0.7 (for science of 2005-06-14 on, for calibrations of 2005-06-19 on). The
first frame of the stack is no longer necessarily in the center of the COADD
product. Several new QC parameters introduced (linearity). Standard star and
PSF products modified.
- 2005-07-20, V 1.0.8 (for science from 2005-06-15 on, for
calibrations of 2005-06-24 on). The size of science COADD products is minimized.
The SKY_MED product is corrected for optical distortion and flatfield. The
median collapsed cube products have WCS included.
- 2006-02-20, V1.2.8
- 2006-02-26, V1.3.0
- 2006-04-01, V1.3.1
- 2006-06-06 V1.3.7 distortion and slit pos improved
- 2006-07-01 V1.3.8 staring mode reduction improved
|
| FILE
FORMAT | | |
SINFONI raw frames before Feb 2005 come in the following format:
- HIERARCH
ESO DET CHIP ID = ESO-Hawaii2RG
- HIERARCH ESO DET CHIP NAME = Hawaii2RG
- HIERARCH
ESO DET CHIP NX = 2048
- HIERARCH ESO DET CHIP NY = 2048
- HIERARCH ESO DET NCORRS NAME = Fowler
SINFONI
raw frames after Feb 2005 come in the following format:
- HIERARCH ESO
DET CHIP ID = ESO-Hawaii2RG
- HIERARCH ESO DET CHIP NAME = Hawaii2RG
- HIERARCH ESO DET
CHIP NX = 2048
- HIERARCH ESO DET CHIP NY = 2048
- HIERARCH ESO DET NCORRS NAME = NonDest
| |
|