        [page auto-refreshes after 300 sec]   [stop | on]            [press Ctrl+Shift+R to enforce refresh of scores, dates and news]
VIMOS trending system: HEALTH CHECK report
HELP USERS-GUIDE MORE
Last update: 2015-08-29T03:38:54 (UT)
  | now: 2015-08-30T07:56:53 (UT) muc03 QC pipeline: vimos-2.9.13 (installed 2015-04-23)
same group: LR_blue LR_red MR HR_blue HR_orange HR_red   LR_blue_all LR_red_all
General news: Please note two new features: 1. 'forced refresh', see button below, right-hand side of 'ngas'. 2. Raw CALIB file screenshots for quality review, last 7 days, behind the 'raw' links.
VIMOS news:  
Report news:
DATE*: [?] 2015-08-23
report | NLT
2015-08-24
report | NLT
2015-08-25
report | NLT
2015-08-26
no data | NLT
2015-08-27
no data | NLT
2015-08-28
no data | NLT
2015-08-29
no data | NLT
r...
Raw CAL displays:
raw raw raw no raw files no raw files no raw files no raw files
P...
Product quality:
products products products no products no products no products no products
 
transfer   ngas [?]

scores&comments | history ... | plot tutorial ... | contact               [?]
*Date on this monitor changes at 21:00 UT
Print: Information and research:
- png file - advanced studies: QC1 browser | QC1 plotter
Plot
?
Symb
?
Source
*
Average ? Thresholds ? N_
data
QC1
parameter
Data
downloads
Remarks
method value unit method value
1 QC1DB MEDIAN 7 none VAL0,50 70 wave_lost2 this | last_yr | all number of lost fibres on pseudo slit 2
2 QC1DB MEDIAN 18 none VAL0,50 70 wave_lost2 this | last_yr | all number of lost fibres on pseudo slit 2
3 QC1DB MEDIAN 20 none VAL0,50 70 wave_lost2 this | last_yr | all number of lost fibres on pseudo slit 2
4 QC1DB MEDIAN 40 none VAL0,50 70 wave_lost2 this | last_yr | all number of lost fibres on pseudo slit 2
*Data sources: QC1DB: QC1 database; LOCAL: local data source
Plot 1
scores: 8|
data source:vimos_ifu_score
(QC1 database)
dataset:wave_lost2
median:7none
fixed thresholds:0...50none
N_data plotted:70
[click on plot for closeup]
Plot 2
scores: 8|
data source:vimos_ifu_score
(QC1 database)
dataset:wave_lost2
median:18none
fixed thresholds:0...50none
N_data plotted:70
[click on plot for closeup]
Plot 3
scores: 8|
data source:vimos_ifu_score
(QC1 database)
dataset:wave_lost2
median:20none
fixed thresholds:0...50none
N_data plotted:70
[click on plot for closeup]
Plot 4
scores: 8|
data source:vimos_ifu_score
(QC1 database)
dataset:wave_lost2
median:40none
fixed thresholds:0...50none
N_data plotted:70
[click on plot for closeup]
This plot

Trending plot for number of not successfully found, traced, and wavelength-calibrated fibres in IFU calibrations.

The LR grisms have four pseudo slits; wave_lost is determined separately for each but scored only for pseudo slit 2. Only measurements executed with IFU shutter OFF are plotted. MR and HR grisms use pseudo slit 2 only.

Historical trending plots show only the number of fibres that could not be successfully identified from IFU flat-field calibrations (QC parameter num_lost). Beginning with October 2009, trending also includes those fibres that could not be wavelength calibrated (QC parameter wave_lost).

Template ID: ifu_cal_DayCalib (daytime Health Checks), ifu_cal_NightCalib (attached night-time). Pipeline recipe: vmifucalib.  


General information

Click on any of the plots to see a close-up version.

The latest date is indicated on top of the plot.

If configured,

  • data points belonging to the latest date are specially marked
  • statistical averages are indicated by a solid line, and thresholds by broken lines
  • outliers are marked by a red asterisk. They are defined as data points outside the threshold lines
  • "aliens" (= data points outside the plot Y limits) are marked by a red arrow ( or )