VIMOS trending system: HEALTH CHECK plot
Last update: 2008-07-05T08:42:40 (UT)
now: 2008-07-06T05:43:39 (UT)
INFO USERS-GUIDE MORE
same group: MEDIAN RMS RON   AVGLOW AVGHIGH
history ... | plot tutorial ...   daily/often; important to check     [info]
last OPSLOG data:
2008-07-05
Plot: 1 2 3 4 5 6 7 8   latest_files
N_data: number of recent OPSLOG entries plotted here
N_data: 18 18 18 19 18 18 18 18 availability
Print: Information and research: News:
- png file - advanced studies: QC1 browser | QC1 plotter
 
Plot
[info]
Symbol
[info]
Source* OPS?** Average [info] Thresholds [info] N_data Data downloads Remarks
method value unit method value
1 QC1DB yes (18) MEDIAN 194.00000 ADU 3SIG± 3.36490 63 this | last_yr | all Q2, median bias, low gain
2 QC1DB yes (18) MEDIAN 196.00000 ADU 3SIG± 1.50269 63 this | last_yr | all Q1, median bias, low gain
3 QC1DB yes (18) MEDIAN 188.00000 ADU 3SIG± 8.73813 63 this | last_yr | all Q2, median bias, high gain
4 QC1DB yes (19) MEDIAN 194.00000 ADU 3SIG± 2.30507 63 this | last_yr | all Q1, median bias, high gain
5 QC1DB yes (18) MEDIAN 199.00000 ADU 3SIG± 3.07809 63 this | last_yr | all Q3, median bias, low gain
6 QC1DB yes (18) MEDIAN 193.00000 ADU 3SIG± 1.70389 63 this | last_yr | all Q4, median bias, low gain
7 QC1DB yes (18) MEDIAN 200.00000 ADU 3SIG± 9.80078 63 this | last_yr | all Q3, median bias, high gain
8 QC1DB yes (18) MEDIAN 194.00000 ADU 3SIG± 2.63178 63 this | last_yr | all Q4, median bias, high gain
*Data sources: QC1DB: QC1 database; LOCAL: local text file | **OPS: to indicate if OPSLOG data are included
This plot

Trending plots for bias QC parameters.

All bias parameters are measured in the central 1600x1800 pixels of the detectors. The median bias level and the rms of the master should show a stable trend without sudden jumps or increase/decrease. The read-out noise is calculated from the difference of the first two raw frames. Some outliers with high values are occasionally observed due to cosmic ray events.

Bias frames are usually measured daily during day-time. They come in two different varieties: with low gain (used for imaging) and with high gain (used to calibrate the spectroscopic modes).  


General information

Click on any of the plots to see a close-up version.

If applicable, the latest values from Paranal ops logs are plotted as blue dots. More information about those values, including a download option, is available in the OPSLOG section on top of the page.

The latest date is indicated on top of the plot, data points belonging to that date are specially marked.

If configured,

  • statistical averages are indicated by a solid line, and thresholds by broken lines
  • outliers are marked by a red asterisk. They are defined as data points outside the threshold lines
  • "aliens" (= data points outside the plot Y limits) are marked by a red arrow ( or )
  • you can download the data for each parameter set if the 'Data downloads' link shows up