          | Plot ?
 | Symb ?
 | Source *
 | Average    ? | Thresholds ? | N_ data
 | QC1 parameter
 | Data downloads
 | Remarks |  
	  | method | value | unit | method | value |  
| 1 |  | QC1DB | MEDIAN | 6 | none | VAL | 0,50 | 73 | wave_lost2 | this |
    last_yr |
    all | number of lost fibres on pseudo slit 2 |  
| 2 |  | QC1DB | MEDIAN | 20 | none | VAL | 0,50 | 73 | wave_lost2 | this |
    last_yr |
    all | number of lost fibres on pseudo slit 2 |  
| 3 |  | QC1DB | MEDIAN | 20 | none | VAL | 0,50 | 73 | wave_lost2 | this |
    last_yr |
    all | number of lost fibres on pseudo slit 2 |  
| 4 |  | QC1DB | MEDIAN | 40 | none | VAL | 0,50 | 73 | wave_lost2 | this |
    last_yr |
    all | number of lost fibres on pseudo slit 2 |  
          |  |  
          | *Data sources: QC1DB: QC1 database; LOCAL: local data source |  
| Plot 1 scores:
  7|               |  | data source: | vimos_ifu_score (QC1 database)
 |  | dataset: | wave_lost2 |  |  | median: | 6 | none |  | fixed thresholds: | 0...50 | none |  | N_data plotted: | 73 |  | [click plot for closeup] | 
| Plot 2 scores:
  7|               |  | data source: | vimos_ifu_score (QC1 database)
 |  | dataset: | wave_lost2 |  |  | median: | 20 | none |  | fixed thresholds: | 0...50 | none |  | N_data plotted: | 73 |  | [click plot for closeup] | 
| Plot 3 scores:
  7|               |  | data source: | vimos_ifu_score (QC1 database)
 |  | dataset: | wave_lost2 |  |  | median: | 20 | none |  | fixed thresholds: | 0...50 | none |  | N_data plotted: | 73 |  | [click plot for closeup] | This plot
| Plot 4 scores:
  7|               |  | data source: | vimos_ifu_score (QC1 database)
 |  | dataset: | wave_lost2 |  |  | median: | 40 | none |  | fixed thresholds: | 0...50 | none |  | N_data plotted: | 73 |  | [click plot for closeup] | 
Trending plot for number of not successfully found, traced, and
wavelength-calibrated fibres in IFU calibrations. 
The LR grisms have four pseudo slits; wave_lost is determined separately for
each but scored only for pseudo slit 2. Only measurements executed with
IFU shutter OFF are plotted. MR and HR grisms use
pseudo slit 2 only.  
Historical trending plots show only the number of fibres that could not be
successfully identified from IFU flat-field calibrations (QC parameter
num_lost). Beginning with
October 2009, trending also includes those fibres that could not be
wavelength calibrated (QC parameter wave_lost).
 
Template ID: ifu_cal_DayCalib (daytime Health Checks), ifu_cal_NightCalib
(attached night-time). Pipeline recipe: vmifucalib.
        
       General information
 
 Click on any of the plots to see a close-up version. The latest date is indicated on top of the plot. If configured, 
data points belonging to the latest date are specially marked
statistical averages are indicated by a solid line, and thresholds by broken lines
outliers are marked by a red asterisk. They are defined as data points outside the
threshold lines
"aliens" (= data points outside the plot Y limits) are marked by a red arrow (↑ or ↓)
you can download the data for each parameter set if the 'Data downloads' link shows up
 |