mirror sites: PL (internal link) HQ     [?]

Health Check monitor

 

CAL | HC | refs | QC
HealthCheck Monitor
   HOME | UsersGuide
  sl icon ALL INSTRUMENTS
 
all KPI reports
CRIRES:
wave
Other HC:
QC links:
        [page auto-refreshes after 300 sec]   [stop | on]            [press Ctrl+Shift+R to enforce refresh of scores, dates and news]
CRIRES trending system: HEALTH CHECK report
HELP USERS-GUIDE MORE
Last update: 2014-07-22T11:33:41 (UT)
  | now: 2024-03-29T01:53:20 (UT) muc01 QC pipeline: crire-2.3.2 (installed 2014-03-18)
same group: xcorr ThAr N2O DISP RESOL   AVG
General news: NOTE: The Health Check and calChecker services are moved to qcFlow on an instrument by instrument basis. The current pages will not be updated any longer once the move has been finished.
CRIRES news:
Report news:
DATE*: [?] 2024-03-22
report | NLT
2024-03-23
report | NLT
2024-03-24
report | NLT
2024-03-25
report | NLT
2024-03-26
report | NLT
2024-03-27
report | NLT
2024-03-28
no data | NLT
r...
Raw CAL displays:
raw raw raw raw raw raw no CAL raw files
P...
CAL product quality:
products products products products products products no CAL products
  last OPSLOG data:
2014-07-16*

last files ...
[an error occurred while processing this directive]
monitor

scores&comments | history ... | plot tutorial ... | contact                 daily/often; important to check     [?]
*Date on this monitor changes at 21:00 UT
Print: Information and research:
- png file - advanced studies: QC1 browser | QC1 plotter
May 2013: change of ThAr Lamp: Discrepancy between the opslog/Paranal (blue points) and the QC/Garching results (different value for the pipeline parameter --wl_log: Flag to use the logarithm of the catalog).
Paranal pipeline parameter value will be updated for next release (April 2014)
Plot
?
Symb
?
Source
*
OPS?
**
Average ? Thresholds ? N_
data
QC1
parameter
Data
downloads
Remarks
method value unit method value
1 QC1DB no MEDIAN   NONE VAL-1,1 0 xcorr this | last_yr | all xcorr, chip 1, WREF=1090.4
2 QC1DB no MEDIAN 0.473 NONE VAL0.44,1 89 xcorr this | last_yr | all xcorr, chip 2, WREF=1090.4
3 QC1DB yes (1) MEDIAN 0.536 NONE VAL0.44,1 89 xcorr this | last_yr | all xcorr, chip 3, WREF=1090.4
4 QC1DB no MEDIAN   NONE VAL-1,1 0 xcorr this | last_yr | all xcorr, chip 4, WREF=1090.4
5 QC1DB yes (1) MEDIAN 0.831 NONE VAL0.48,1 89 xcorr this | last_yr | all xcorr, chip 1, WREF=4092.9
6 QC1DB yes (1) MEDIAN 0.865 NONE VAL0.48,1 89 xcorr this | last_yr | all xcorr, chip 2, WREF=4092.9
7 QC1DB yes (1) MEDIAN 0.809 NONE VAL0.48,1 89 xcorr this | last_yr | all xcorr, chip 3, WREF=4092.9
8 QC1DB no MEDIAN 0.824 NONE VAL0.48,1 89 xcorr this | last_yr | all xcorr, chip 4, WREF=4092.9
*Data sources: QC1DB: QC1 database; LOCAL: local text file | **OPS: OPSLOG data are included
Plot 1
scores: no current data
data source:crires_wave
(QC1 database)
dataset:xcorr
median:no dataNONE
fixed thresholds:-1...1NONE
N_data plotted:0
[click on plot for closeup]
Plot 2
scores: 8|
data source:crires_wave
(QC1 database)
dataset:xcorr
median:0.473NONE
fixed thresholds:0.44...1NONE
N_data plotted:89
[click on plot for closeup]
Plot 3
scores: 8|
data source:crires_wave
(QC1 database)
dataset:xcorr
median:0.536NONE
fixed thresholds:0.44...1NONE
N_data plotted:89
[click on plot for closeup]
Plot 4
scores: no current data
data source:crires_wave
(QC1 database)
dataset:xcorr
median:no dataNONE
fixed thresholds:-1...1NONE
N_data plotted:0
[click on plot for closeup]
Plot 5
scores: 9|
data source:crires_wave
(QC1 database)
dataset:xcorr
median:0.831NONE
fixed thresholds:0.48...1NONE
N_data plotted:89
[click on plot for closeup]
Plot 6
scores: 9|
data source:crires_wave
(QC1 database)
dataset:xcorr
median:0.865NONE
fixed thresholds:0.48...1NONE
N_data plotted:89
[click on plot for closeup]
Plot 7
scores: 9|
data source:crires_wave
(QC1 database)
dataset:xcorr
median:0.809NONE
fixed thresholds:0.48...1NONE
N_data plotted:89
[click on plot for closeup]
Plot 8
scores: 9|
data source:crires_wave
(QC1 database)
dataset:xcorr
median:0.824NONE
fixed thresholds:0.48...1NONE
N_data plotted:89
[click on plot for closeup]
This plot

Wavelength calibration: trending of cross correlation results.

The cross correlation result is a unitless number between 0 and 1. Values above 0.2 are regarded as acceptable. For lower values, the CRIRES pipeline disregards the result and returns -1. Such values are marked as "aliens" (red arrows) in the plots.

The cross correlation results are monitored for the two daily health check settings with reference wavelength (on chip 3) of 1090.4nm using ThAr lamp and 4092.9nm using N2O absorption cell.

Chips 1 and 4 of the 1090.4 nm setting suffer from vignetting. Pipeline results are arbitrary and are not plotted.

Pipeline processing in Garching applies dark subtraction and flat-fielding.  


General information

Click on any of the plots to see a close-up version.

If applicable, the latest values from Paranal ops logs are plotted as blue dots. More information about those values, including a download option, is available in the OPS column.

The latest date is indicated on top of the plot, data points belonging to that date are specially marked.

If configured,

  • statistical averages are indicated by a solid line, and thresholds by broken lines
  • outliers are marked by a red asterisk. They are defined as data points outside the threshold lines
  • "aliens" (= data points outside the plot Y limits) are marked by a red arrow ( or )
  • you can download the data for each parameter set if the 'Data downloads' link shows up