mirror sites: PL (internal link) HQ     [?]

Health Check monitor

 

CAL | HC | refs | QC
HealthCheck Monitor
   HOME | UsersGuide
  sl icon ALL INSTRUMENTS
 
all KPI reports
XSHOOTER:
lamps: arc & flat
Other HC:
QC links:
        [page auto-refreshes after 300 sec]   [stop | on]            [press Ctrl+Shift+R to enforce refresh of scores, dates and news]
XSHOOTER trending system: HEALTH CHECK report
HELP USERS-GUIDE MORE
Last update: 2022-08-11T22:38:39 (UT)
  | now: 2022-08-12T08:58:37 (UT) muc02 QC pipeline: xshoo-3.6.0 (installed 2022-03-21)
same group: flat_HC_IFU slice_rms   flat_IFU flat_SLIT arc_lamp spectrum SLIT stdev
General news:
XSHOOTER news:  
Report news:
DATE*: [?] 2022-08-05
report | NLT
2022-08-06
report | NLT
2022-08-07
report | NLT
2022-08-08
report | NLT
2022-08-09
report | NLT
2022-08-10
report | NLT
2022-08-11
report | NLT
r...
Raw CAL displays:
raw raw raw raw raw raw raw
P...
CAL product quality:
products products products products products products products
 
transfer   ngas [?]

scores&comments | history ... | plot tutorial ... | contact | HC_docu... | quality events...               [?]
*Date on this monitor changes at 21:00 UT
png: Information and research:
- png file - advanced studies: QC1 browser | QC1 plotter
Plot
?
Symb
?
Source
*
Average ? Thresholds ? N_
data
QC1
parameter
Data
downloads
Remarks
method value unit method value
1 QC1DB none   ADU/sec VAL750,5500 39 flux_1 this | last_yr | all lamp flux [ADU/s] in flat for 0.9x11 slit vs. time
2 QC1DB none   ADU none  39 counts_1 this | last_yr | all maximum counts [ADU] in flat for 0.9x11 slit vs. time
2 QC1DB none   ADU VAL20000,50000 289 counts_1 this | last_yr | all maximum counts [ADU] in flat for any slit vs. time
3 QC1DB none   ADU none  289 counts_1 this | last_yr | all maximum counts [ADU] in flat vs. slit width
*Data sources: QC1DB: QC1 database; LOCAL: local data source
Plot 1
scores: not implemented
data source:xshooter_flat
(QC1 database)
dataset:flux_1
average:none
fixed thresholds:750...5500ADU/sec
N_data plotted:39
[click plot for closeup]
Plot 2
scores: 3|
data source:xshooter_flat
(QC1 database)
dataset:
(numbers below apply to this dataset)
counts_1
average:none
thresholds:none
N_data plotted:39
[click plot for closeup]
Plot 3
scores: not implemented
data source:xshooter_flat
(QC1 database)
dataset:counts_1
average:none
thresholds:none
N_data plotted:289
[click plot for closeup]
This plot

The lamp flux [ ADU/sec] and the flat counts are monitored in NIR-arm calibration flat frames. They are composed of ten raw frames (five on-lamp frames and five off-lamp frames).

Only frames with slit 0.9x11 are scored.

For more information see the plot tutorial page.  


General information

Click on any of the plots to see a close-up version.

The latest date is indicated on top of the plot.

If configured,

  • data points belonging to the latest date are specially marked
  • statistical averages are indicated by a solid line, and thresholds by broken lines
  • outliers are marked by a red asterisk. They are defined as data points outside the threshold lines
  • "aliens" (= data points outside the plot Y limits) are marked by a red arrow ( or )
  • you can download the data for each parameter set if the 'Data downloads' link shows up