mirror sites: PL (internal link) HQ     [?]

Health Check monitor

 

CAL | HC | refs | QC
HealthCheck Monitor
   HOME | UsersGuide
  sl icon ALL INSTRUMENTS
 
all KPI reports
XSHOOTER:
distortion correction
Other HC:
QC links:
        [page auto-refreshes after 300 sec]   [stop | on]            [press Ctrl+Shift+R to enforce refresh of scores, dates and news]
XSHOOTER trending system: HEALTH CHECK report
HELP USERS-GUIDE MORE
Last update: 2024-03-18T22:38:20 (UT)
  | now: 2024-03-19T05:57:33 (UT) muc02 QC pipeline: xshoo-3.6.5a (installed 2023-09-18)
same group: number_identified gaps fmt_resid order_resid 2d_resid
General news: NOTE: The Health Check and calChecker services are moved to qcFlow on an instrument by instrument basis. The current pages will not be updated any longer once the move has been finished.
XSHOOTER news:  
Report news: 2022-07-19 Test of a new ThAr lamp during 2022-07-16T16:00 to 2022-07-18T17:00. Please ignore the wrong behaviour during this period. The data points correspond to a test. IS and QC1 are aware [melipal@eso.org]
DATE*: [?] 2024-03-12
report | NLT
2024-03-13
report | NLT
2024-03-14
report | NLT
2024-03-15
report | NLT
2024-03-16
report | NLT
2024-03-17
report | NLT
2024-03-18
report | NLT
r...
Raw CAL displays:
raw raw raw raw raw raw raw
P...
CAL product quality:
products products products products products products products
 
transfer   ngas [?]

scores&comments | FULL | history ... | plot tutorial ... | contact | HC_docu... | quality events...               [?]
*Date on this monitor changes at 21:00 UT
png: Information and research:
- png file - advanced studies: QC1 browser | QC1 plotter
Plot
?
Symb
?
Source
*
Average ? Thresholds ? N_
data
QC1
parameter
Data
downloads
Remarks
method value unit method value
1 QC1DB MEDIAN 379 NONE VAL330,420 94 nline_found_clean this | last_yr | all number of lines identified in format check (= 1pinhole arc)
2 QC1DB MEDIAN 368 NONE VAL350,390 90 nline_found_clean this | last_yr | all number of lines identified in 2dmap, divided by 9
3 QC1DB MEDIAN 12 NONE VAL12,12 90 n_order_det this | last_yr | all number of detected orders from 1 pinhole flat
*Data sources: QC1DB: QC1 database; LOCAL: local data source
Plot 1
scores: 5|
data source:xshooter_format
(QC1 database)
dataset:nline_found_clean
median:379NONE
fixed thresholds:330...420NONE
N_data plotted:94
[click plot for closeup]
Plot 3
scores: 4|
data source:xshooter_order
(QC1 database)
dataset:n_order_det
median:12NONE
fixed thresholds:12...12NONE
N_data plotted:90
[click plot for closeup]
Plot 2
scores: 4|
data source:xshooter_2dmap
(QC1 database)
dataset:nline_found_clean
median:368NONE
fixed thresholds:350...390NONE
N_data plotted:90
[click plot for closeup]
This plot

This plot shows

  • the number of identified arc lines in (RAW_TYPE = FMTCHK, recipe = xsh_predict, 1 single-pinhole) frames
  • the number of identified arc lines in (RAW_TYPE = WAVE, recipe = xsh_2dmap, 1 9-pinhole arc) frames
  • the number of identified orders (RAW_TYPE = ORDERDEF, recipe = xsh_orderpos, 1 flat and 1 single-pinhole) frames
More information can be found in the plot tutorial page.  
General information

Click on any of the plots to see a close-up version.

The latest date is indicated on top of the plot.

If configured,

  • data points belonging to the latest date are specially marked
  • statistical averages are indicated by a solid line, and thresholds by broken lines
  • outliers are marked by a red asterisk. They are defined as data points outside the threshold lines
  • "aliens" (= data points outside the plot Y limits) are marked by a red arrow ( or )
  • you can download the data for each parameter set if the 'Data downloads' link shows up