mirror sites: PL (internal link) HQ     [?]

Health Check monitor

 

CAL | HC | refs | QC
HealthCheck Monitor
   HOME | UsersGuide
  sl icon ALL INSTRUMENTS
 
FULL reports
VIMOS:
IFU efficiency
Other HC:
QC links:
        [page auto-refreshes after 300 sec]   [stop | on]            [press Ctrl+Shift+R to enforce refresh of scores, dates and news]
VIMOS trending system: HEALTH CHECK report
HELP USERS-GUIDE MORE
Last update: 2014-07-24T03:40:42 (UT)
  | now: 2014-07-24T20:44:55 (UT) muc03 QC pipeline: vimos-2.9.13 (installed 2014-03-19)
same group: LR_blue LR_red MR HR_blue HR_orange HR_red
General news:
VIMOS news:  
Report news:
DATE*: [?] 2014-07-17
report | NLT
2014-07-18
report | NLT
2014-07-19
report | NLT
2014-07-20
report | NLT
2014-07-21
report | NLT
2014-07-22
report | NLT
2014-07-23
report | NLT
P...
Product quality:
products products products products products products products
  no OPSLOG data  

scores&comments | FULL | history ... | plot tutorial ... | contact               [?]
*Date on this monitor changes at 21:00 UT
Print: Information and research:
- png file - advanced studies: QC1 browser | QC1 plotter
Plot
?
Symb
?
Source
*
OPS?
**
Average ? Thresholds ? N_
data
QC1
parameter
Data
downloads
Remarks
method value unit method value
1 QC1DB no MEDIAN   none VAL0.05,0.12 0 efficiency4 this | last_yr | all efficiency at 4900A, IFU mag 1:1
2 QC1DB no MEDIAN   none VAL0.05,0.14 0 efficiency4 this | last_yr | all efficiency at 4900A, IFU mag 1:1
3 QC1DB no MEDIAN   none VAL0.05,0.10 0 efficiency4 this | last_yr | all efficiency at 4900A, IFU mag 1:1
4 QC1DB no MEDIAN   none VAL0.05,0.13 0 efficiency4 this | last_yr | all efficiency at 4900A, IFU mag 1:1
*Data sources: QC1DB: QC1 database; LOCAL: local text file | **OPS: OPSLOG data are included
Plot 1
scores: 1|
data source:vimos_ifu_std
(QC1 database)
dataset:efficiency4
median:no datanone
fixed thresholds:0.05...0.12none
N_data plotted:0
[click on plot for closeup]
Plot 2
scores: 1|
data source:vimos_ifu_std
(QC1 database)
dataset:efficiency4
median:no datanone
fixed thresholds:0.05...0.14none
N_data plotted:0
[click on plot for closeup]
Plot 3
scores: 1|
data source:vimos_ifu_std
(QC1 database)
dataset:efficiency4
median:no datanone
fixed thresholds:0.05...0.1none
N_data plotted:0
[click on plot for closeup]
Plot 4
scores: 1|
data source:vimos_ifu_std
(QC1 database)
dataset:efficiency4
median:no datanone
fixed thresholds:0.05...0.13none
N_data plotted:0
[click on plot for closeup]
This plot

Trending plot for the overall IFU efficiency, measured using spectrophotometric standard stars.

The following settings are used:
LR_blue grism + OS-blue filter
LR_red grism + OS-red filter
MR grism + GG475 filter
HR_blue grism (without filter)
HR_orange grism + GG435 filter
HR_red grism + GG475 filter

For the MR and HR grisms, both IFU magnification configurations (1:1, 2:1) are plotted but only 1:1 is scored.

Template ID: ifu_cal_Specphot. Pipeline recipe: vmifustandard.

Plots that show the efficiency vs. wavelength have been created by averaging several standard star measurements. They show the efficiency before and after the 2010 instrument upgrade. Measurements with the new HR_blue grism after April 2012 are included here.  


General information

Click on any of the plots to see a close-up version. The latest date is indicated on top of the plot, data points belonging to that date are specially marked.

If configured,

  • statistical averages are indicated by a solid line, and thresholds by broken lines
  • outliers are marked by a red asterisk. They are defined as data points outside the threshold lines
  • "aliens" (= data points outside the plot Y limits) are marked by a red arrow ( or )
  • you can download the data for each parameter set if the 'Data downloads' link shows up