mirror sites: PL HQ

Health Check monitor

 

CAL | HC | refs | QC
HealthCheck Monitor
   HOME | UsersGuide
  sl icon ALL INSTRUMENTS
VIMOS:
IFU stability
Other HC:
QC links:
        [page auto-refreshes after 300 sec]   [stop | on]            [press Ctrl+R to enforce refresh of scores and dates]
VIMOS trending system: HEALTH CHECK report
Last update: 2012-05-24T14:20:26 (UT)
| now: 2012-05-24T17:25:03 (UT)
HELP USERS-GUIDE MORE
same group: LR_blue LR_red MR HR_blue HR_orange HR_red
General news: 2012-05-24: The HC monitors for OMEGACAM, VIRCAM and HAWKI are back. Population with current data is in progress.
VIMOS news:  
Report news:  
DATE*: [?] 2012-05-17
report | NR
2012-05-18
report | NR
2012-05-19
report | NR
2012-05-20
report | NR
2012-05-21
report | NR
2012-05-22
report | NR
2012-05-23
report | NR
P...
Product quality:
products products products products products products products
  last OPSLOG data:
2012-05-20*

last files ...
monitor

scores&comments | history ... | plot tutorial ... | contact               [?]
*Date on this monitor changes at 21:00 UT
Print: Information and research:
- png file - advanced studies: QC1 browser | QC1 plotter
Plot
?
Symb
?
Source
*
OPS?
**
Average ? Thresholds ? N_
data
QC1
parameter
Data
downloads
Remarks
method value unit method value
1 QC1DB yes (1) MEDIAN 209 num VAL204,208 60 trace2_central this | last_yr | all Q2, central fibre number
2 QC1DB yes (1) MEDIAN 200 num VAL198,202 60 trace2_central this | last_yr | all Q1, central fibre number
3 QC1DB yes (1) MEDIAN 203 num VAL201,205 60 trace2_central this | last_yr | all Q3, central fibre number
4 QC1DB yes (1) MEDIAN 201 num VAL198,202 60 trace2_central this | last_yr | all Q4, central fibre number
*Data sources: QC1DB: QC1 database; LOCAL: local text file | **OPS: to indicate that OPSLOG data are included
Plot 1
scores: 11|
data source:vimos_ifu_score
(QC1 database)
dataset:trace2_central
median:209num
fixed thresholds:204...208num
N_data plotted:60
[click on plot for closeup]
Plot 2
scores: 11|
data source:vimos_ifu_score
(QC1 database)
dataset:trace2_central
median:200num
fixed thresholds:198...202num
N_data plotted:60
[click on plot for closeup]
Plot 3
scores: 11|
data source:vimos_ifu_score
(QC1 database)
dataset:trace2_central
median:203num
fixed thresholds:201...205num
N_data plotted:60
[click on plot for closeup]
Plot 4
scores: 11|
data source:vimos_ifu_score
(QC1 database)
dataset:trace2_central
median:201num
fixed thresholds:198...202num
N_data plotted:60
[click on plot for closeup]
This plot

Trending plot for the central fibre in IFU calibrations.

The central fibre number should vary only by about +/- 2.

Setting HR_orange is usually measured daily; other settings only when science frames have been observed. For LR grisms, only data with IFU shutter OFF are plotted.

Template ID: ifu_cal_DayCalib (daytime Health Checks), ifu_cal_NightCalib (attached night-time). Pipeline recipe: vmifucalib.  


General information

Click on any of the plots to see a close-up version.

If applicable, the latest values from Paranal ops logs are plotted as blue dots. More information about those values, including a download option, is available in the OPS column.

The latest date is indicated on top of the plot, data points belonging to that date are specially marked.

If configured,

  • statistical averages are indicated by a solid line, and thresholds by broken lines
  • outliers are marked by a red asterisk. They are defined as data points outside the threshold lines
  • "aliens" (= data points outside the plot Y limits) are marked by a red arrow ( or )
  • you can download the data for each parameter set if the 'Data downloads' link shows up