NaCoM' photometric standards, VIS/JHK dichroic |
|||||
|
| Name | RA(J2000) | DEC(J2000) | SpT | J | Err J | H | Err H | K | Err K | L | Err L | L' | Err L' | M | Err M |
| HR0088 | 00 22 50 | -12 12 37 | G3V | 5.302 | 0.011 | 4.970 | 0.006 | 4.913 | 0.006 | 4.896 | 0.021 | 4.976 | 0.008 | ||
| HR0721 | 02 26 59 | -47 42 14 | B5IV | 4.518 | 0.011 | 4.556 | 0.006 | 4.605 | 0.009 | 4.650 | 0.016 | 4.612 | 0.030 | ||
| HR2290 | 06 20 05 | -48 44 15 | G3V | 5.520 | 0.015 | 5.189 | 0.013 | 5.141 | 0.012 | 5.123 | 0.010 | 5.118 | 0.060 | ||
| HR2354 | 06 24 26 | -63 25 39 | G3III-IV | 5.375 | 0.022 | 5.053 | 0.012 | 5.004 | 0.010 | 4.989 | 0.020 | 5.003 | 0.017 | ||
| HR2318 | 06 24 45 | -28 46 42 | G2IV | 5.284 | 0.029 | 4.971 | 0.013 | 4.923 | 0.008 | 4.908 | 0.015 | 4.850 | 0.056 | ||
| HR2668 | 07 03 59 | -43 37 01 | K0V | 5.507 | 0.017 | 5.078 | 0.008 | 5.018 | 0.013 | 4.974 | 0.008 | 5.068 | 0.049 | ||
| HR2882 | 07 30 43 | -37 20 25 | G4V | 5.562 | 0.023 | 5.224 | 0.011 | 5.170 | 0.017 | 5.146 | 0.025 | 5.137 | 0.063 | ||
| HR5249 | 13 58 41 | -44 48 11 | B2IV-V | 4.342 | 0.010 | 4.430 | 0.012 | 4.507 | 0.010 | 4.575 | 0.014 | 4.534 | 0.032 | ||
| HR5384 | 14 23 14 | +01 14 54 | G1V | 5.126 | 0.012 | 4.749 | 0.009 | 4.703 | 0.006 | 4.571 | 0.023 | 4.597 | 0.014 | ||
| HR6070 | 16 18 18 | -28 36 46 | A0V | 4.831 | 0.005 | 4.799 | 0.016 | 4.813 | 0.006 | 4.807 | 0.006 | 4.717 | 0.077 | ||
| HR6736 | 18 03 52 | -24 21 38 | O8Iab: | 5.817 | 0.012 | 5.773 | 0.012 | 5.796 | 0.007 | 5.819 | 0.017 | 5.802 | 0.054 | ||
| HR7446 | 19 36 53 | -07 01 39 | B0.5III | 4.991 | 0.010 | 5.000 | 0.012 | 5.028 | 0.010 | 5.055 | 0.010 | 4.996 | 0.040 | ||
| HR7773 | 20 20 40 | -12 45 32 | B9IV | 4.842 | 0.015 | 4.846 | 0.011 | 4.859 | 0.010 | 4.893 | 0.006 | 4.887 | 0.040 | ||
| HR8042 | 21 02 12 | -43 00 02 | G3IV+ | 5.511 | 0.012 | 5.141 | 0.010 | 5.085 | 0.007 | 5.053 | 0.008 | 5.066 | 0.014 | ||
| HR8477 | 22 14 36 | -41 22 15 | G5V | 5.100 | 0.014 | 4.743 | 0.013 | 4.695 | 0.012 | 4.683 | 0.006 | 4.678 | 0.010 | ||
| HR8700 | 22 53 37 | -48 35 50 | G0V | 5.013 | 0.011 | 4.699 | 0.009 | 4.657 | 0.009 | 4.636 | 0.013 | 4.638 | 0.012 | ||
| HR8701 | 22 54 40 | -70 04 30 | G2.5IV | 4.973 | 0.017 | 4.641 | 0.007 | 4.591 | 0.005 | 4.566 | 0.009 | 4.550 | 0.019 | ||
| HR9076 | 23 59 55 | -65 34 37 | B9IV | 4.616 | 0.007 | 4.623 | 0.006 | 4.642 | 0.005 | 4.636 | 0.005 | 4.660 | 0.043 |
| Name | RA(J2000) | DEC(J2000) | SpT | J | Err J | H | Err H | K | Err K | L | Err L | L' | Err L' | M | Err M |
| BS 1140 | 03 44 48.215 | +24 17 22.09 | B7IV | 5.520 | 5.500 | 5.510 | 5.60 | 5.64 | 5.64 | ||||||
| HD 40335 | 05 58 13.523 | +01 51 23.00 | A0 | 6.555 | 6.473 | 6.452 | 6.43 | 6.43 | 6.41 | ||||||
| HD 77281 | 09 01 38.010 | -01 28 34.76 | A2 | 7.111 | 7.052 | 7.031 | 7.00 | 7.06 | 6.97 | ||||||
| HD106965 | 12 17 57.543 | +01 34 31.14 | A2 | 7.380 | 7.337 | 7.316 | 7.30 | 7.34 | 7.30 | ||||||
| HD161903 | 17 48 19.224 | -01 48 29.72 | A2 | 7.172 | 7.059 | 7.023 | 6.99 | 7.01 | 7.14 | ||||||
| GL 811.1 | 20 56 46.605 | -10 26 54.61 | dM4 | 7.832 | 7.185 | 6.946 | 6.70 | 6.69 | 6.68 |
|
|