JHKs photometric standards, N90C10 dichroic
Van der Bliek IR photometric standards: See van der Bliek et al. 1996, A&AS, 119, 547
-
Name RA(J2000) DEC(J2000) SpT J Err J H Err H K Err K L Err L M Err M HD590 00 10 12 -18 51 00 F2V 9.200 0.015 8.982 0.026 8.959 0.012 8.892 0.017
HD1274 00 16 37 -63 51 33 G5V 8.795 0.017 8.432 0.011 8.367 0.005 8.362 0.014
HD7644 01 15 36 -45 26 00 F6V 9.504 0.007 9.259 0.005 9.216 0.007
HD8864 01 27 29 +04 27 44 A5 8.632 0.012 8.508 0.009 8.483 0.006
HD15189 02 26 26 -13 52 46 G0V 8.474 0.021 8.183 0.012 8.145 0.007
HD16031 02 34 11 -12 22 54 F0V 8.809 0.031 8.521 0.005 8.495 0.015
HD18847 03 01 25 -19 59 15 F5V 9.033 0.017 8.721 0.008 8.689 0.009
HD20223 03 13 26 -43 21 57 A9V 8.841 0.006 8.696 0.010 8.668 0.010
HD29250 04 35 13 -29 38 12 A4IV 9.508 0.022 9.388 0.010 9.381 0.011
HD60778 07 36 12 -00 08 13 A1V 8.787 0.007 8.714 0.005 8.692 0.019 8.712 0.027
HD110621 12 43 44 -44 40 30 F8 8.952 0.005 8.613 0.008 8.577 0.007
SAO245532 18 32 08 -59 27 42 F9 8.884 0.005 8.612 0.006 8.567 0.005
HD188112 19 54 31 -28 20 22 B9V 10.708 0.006 10.787 0.005 10.860 0.017
HD202964 21 20 21 -38 24 16 F3V 8.652 0.005 8.323 0.005 8.280 0.012
HD207288 21 48 18 -17 37 00 G8V 8.838 0.005 8.394 0.005 8.329 0.005
HD210427 22 10 48 -26 53 00 G1V 9.306 0.021 8.975 0.022 8.917 0.016 8.946 0.021
HD210863 22 13 26 -08 13 46 G0 8.615 0.013 8.299 0.005 8.260 0.005
HD211131 22 15 30 -29 07 00 G8V 8.535 0.009 8.061 0.010 8.000 0.025
HD212874 22 27 19 +04 02 51 A2 9.092 0.005 8.928 0.005 8.908 0.006
HD214497 22 38 48 -14 48 00 F6V 9.259 0.018 8.973 0.007 8.937 0.005
HD218814 23 11 42 -56 47 23 A6V 9.367 0.010 9.265 0.005 9.246 0.005
HD221462 23 32 27 -24 55 55 G3V 8.643 0.016 8.295 0.009 8.250 0.005
-
Name HST RA (J2000) DEC (J2000) J Err J H Err H K Err K Ks Err Ks 9103 S294-D 00:33:15.2 -39:24:10 10.932 0.006 10.657 0.004 10.596 0.005 10.594 0.004 9104 S754-C 01:03:15.8 -04:20:44 11.045 0.005 10.750 0.005 10.693 0.010 10.695 0.005 9105 P530-D 02:33:32.1 06:25:38 11.309 0.010 10.975 0.006 10.897 0.006 10.910 0.005 9111 S361-D 04:49:54.6 -35:11:17 11.246 0.006 11.031 0.006 10.992 0.033 10.980 0.006 9113 S252-D 05:10:25.6 -44:52:46 11.059 0.005 10.776 0.005 10.708 0.034 10.713 0.005 9125 S005-D 07:19:38.6 -84:35:06 10.885 0.007 10.598 0.006 10.514 0.013 10.522 0.008 9129 S209-D 08:01:15.4 -50:19:33 10.914 0.007 10.585 0.006 10.487 0.021 10.496 0.009 9137 S372-S 09:15:50.5 -36:32:34 11.153 0.007 10.891 0.007 10.830 0.019 10.836 0.010 9138 S852-C 09:41:35.8 00:33:12 11.354 0.006 11.041 0.006 10.981 0.015 10.982 0.008 9141 S708-D 09:48:56.4 -10:30:32 11.081 0.008 10.775 0.008 10.715 0.035 10.718 0.010 9154 S008-D 14:23:45.5 -84:09:58 11.232 0.007 10.990 0.007 10.904 0.009 10.915 0.008 9157 S273-E 14:56:51.9 -44:49:14 11.341 0.007 10.924 0.005 10.851 0.004 10.849 0.004 9160 S870-T 15:39:03.5 00:14:54 10.914 0.008 10.701 0.008 10.649 0.010 10.659 0.009 9170 S875-C 17:27:22.2 -00:19:25 11.132 0.005 10.835 0.005 10.739 0.006 10.744 0.005 9173 S024-D 18:18:46.2 -80:06:58 11.039 0.007 10.778 0.007 10.693 0.009 10.711 0.008 9178 S808-C 19:01:55.4 -04:29:12 10.966 0.007 10.658 0.008 10.566 0.014 10.575 0.008