Van der Bliek IR photometric standards

Name RA (2000) Dec (2000) Sp. type J Err. J HErr. H K Err. K L Err. L M Err. M
HD590 00 10 12 -18 51 F2V 9.200 0.015 8.982 0.026 8.959 0.012 8.892 0.017

HR0033 00 11 16 -15 27 52 F5V 3.988 0.012 3.697 0.009 3.665 0.009 3.634 0.005 3.640 0.031
HD1160 00 15 57 +04 15 04 A0 7.073 0.006 7.047 0.005 7.052 0.005 7.065 0.011

HD1274 00 16 37 -63 51 33 G5V 8.795 0.017 8.432 0.011 8.367 0.005 8.362 0.014

HR0077 00 19 51 -64 53 28 F9V 3.224 0.006 2.893 0.007 2.848 0.008 2.815 0.007 2.828 0.027
HR0088 00 22 50 -12 12 37 G3V 5.302 0.011 4.970 0.006 4.913 0.006 4.896 0.021 4.976 0.008
HR0098 00 25 12 -77 15 32 G2IV 1.726 0.013 1.395 0.007 1.353 0.015 1.317 0.008 1.325 0.009
HR0100 00 26 12 -43 40 50 A7V 3.655 0.010 3.564 0.009 3.549 0.010 3.545 0.006 3.517 0.010
HD2811 00 31 18 -43 36 24 A3V 7.207 0.010 7.106 0.009 7.090 0.009 7.072 0.008

HD3567 00 38 32 -08 18 07 F5V 8.263 0.022 7.968 0.005 7.931 0.005



HR0180 00 41 20 -46 05 06 G8III 3.034 0.012 2.488 0.018 2.397 0.013 2.322 0.011 2.425 0.016
HR0188 00 43 34 -17 59 14 K0III 0.424 0.011 -0.108 0.007 -0.208 0.005 -0.275 0.008 -0.190 0.005
HD4306 00 45 27 -09 32 41 G0 7.449 0.020 6.962 0.005 6.885 0.005 6.818 0.016

HD7644 01 15 36 -45 26 F6V 9.504 0.007 9.259 0.005 9.216 0.007



HD8864 01 27 29 +04 27 44 A5 8.632 0.012 8.508 0.009 8.483 0.006



HR0434 01 30 10 +06 08 40 K4III 2.470 0.008 1.708 0.009 1.559 0.011



HR0440 01 31 14 -49 04 30 G9III 2.314 0.006 1.760 0.005 1.674 0.005 1.611 0.007 1.713 0.005
HR0448 01 33 42 -07 01 27 G2IV 4.701 0.008 4.373 0.006 4.324 0.007 4.295 0.005

HR0509 01 44 10 -15 56 58 G8V 2.228 0.015 1.791 0.006 1.732 0.008 1.693 0.006 1.707 0.009
HR0519 01 46 06 -50 48 58 M3III 2.170 0.030 1.295 0.018 1.078 0.005 0.900 0.016 1.178 0.013
HR0591 01 58 44 -61 34 13 F0V 2.363 0.022 2.196 0.009 2.150 0.007 2.115 0.008 2.084 0.020
HR0607 02 03 11 +00 07 41 A5III 5.158 0.016 5.057 0.008 5.047 0.006



HR0705 02 21 45 -68 39 34 A3V 4.016 0.005 3.986 0.005 3.985 0.005 3.973 0.005 3.952 0.032
HD15189 02 26 26 -13 52 46 G0V 8.474 0.021 8.183 0.012 8.145 0.007



HR0721 02 26 59 -47 42 14 B5IV 4.518 0.011 4.556 0.006 4.605 0.009 4.650 0.016 4.612 0.030
HR0718 02 28 09 +08 27 36 B9III 4.403 0.015 4.407 0.009 4.421 0.008 4.431 0.009 4.451 0.065
HD16031 02 34 11 -12 22 54 F0V 8.809 0.031 8.521 0.005 8.495 0.015



HR0806 02 39 35 -68 16 01 B9V 4.235 0.005 4.254 0.005 4.276 0.005 4.289 0.008 4.297 0.017
HR0794 02 40 39 -39 51 18 K0III 2.434 0.012 1.838 0.010 1.745 0.008 1.680 0.009 1.758 0.005
GJ105.5 02 40 42 +01 11 43 M0V:p 7.308 0.017 6.653 0.014 6.542 0.012 6.470 0.017

HR0818 02 45 05 -18 34 23 F5/F6V 3.617 0.016 3.379 0.008 3.347 0.005 3.325 0.008 3.309 0.022
HR0841 02 49 05 -32 24 30 G8.5IIIb 2.808 0.014 2.248 0.013 2.165 0.012 2.096 0.008 2.197 0.010
HR0850 02 51 02 -21 00 14 K0III 3.283 0.009 2.793 0.007 2.713 0.006



HD18847 03 01 25 -19 59 15 F5V 9.033 0.017 8.721 0.008 8.689 0.009



HR0919 03 02 24 -23 37 26 A4V 3.832 0.015 3.725 0.013 3.705 0.005 3.695 0.012 3.673 0.006
HD19904 03 10 43 -39 03 06 A4III/IV 6.758 0.009 6.676 0.008 6.664 0.007 6.642 0.005

HD20223 03 13 26 -43 21 57 A9V 8.841 0.006 8.696 0.010 8.668 0.010



HR1006 03 17 36 -62 35 04 G2.5V 4.405 0.007 4.043 0.006 3.998 0.006



HR0996 03 19 21 +03 22 08 G5V 3.731 0.010 3.374 0.005 3.317 0.005



HR1008 03 19 42 -43 04 48 G8V 3.006 0.008 2.596 0.008 2.547 0.014 2.506 0.005 2.523 0.013
HR1084 03 32 59 -09 27 31 K2V 2.258 0.014 1.764 0.007 1.688 0.008 1.642 0.005 1.697 0.013
HD22686 03 38 55 +02 45 50 A0 7.207 0.022 7.188 0.005 7.198 0.005 7.200 0.020

HR1195 03 49 27 -36 11 59 G9II-III 2.667 0.015 2.184 0.019 2.100 0.010 2.034 0.005 2.110 0.014
HR1294 04 07 20 -64 13 37 G3V 5.248 0.015 4.893 0.006 4.835 0.005



HR1302 04 10 50 -41 59 40 A9V 4.322 0.007 4.137 0.005 4.103 0.005 4.077 0.008 4.055 0.013
HR1326 04 14 00 -42 17 30 K1III 2.088 0.032 1.459 0.016 1.356 0.015 1.277 0.018 1.400 0.012
HD28099 04 26 40 +16 44 50 G2V 7.040 0.010 6.667 0.010 6.613 0.009 6.568 0.016

HR1453 04 33 31 -29 45 46 G6III 2.863 0.016 2.302 0.010 2.222 0.008 2.146 0.005 2.222 0.011
HD29250 04 35 13 -29 38 12 A4IV 9.508 0.022 9.388 0.010 9.381 0.011



HR1464 04 35 33 -30 33 44 G8IIIa 2.294 0.013 1.783 0.014 1.699 0.011 1.628 0.012 1.719 0.014
HR1756 05 19 34 -13 10 36 B0.5IV 4.893 0.014 4.994 0.005 5.086 0.007 5.169 0.005

HR1790 05 25 08 +06 20 59 B2III 2.154 0.016 2.228 0.009 2.295 0.012 2.345 0.015 2.309 0.043
HR1891 05 35 22 -04 25 28 B2.5V 6.592 0.011 6.631 0.006 6.680 0.006



HR1899 05 35 26 -05 54 36 O9III 3.322 0.006 3.413 0.007 3.495 0.009 3.560 0.006

HD38150 05 38 26 -67 11 10 F8V 8.206 0.007 7.922 0.005 7.888 0.005



HR1950 05 40 37 -02 49 31 B1.5V 6.699 0.015 6.780 0.007 6.858 0.006



HR1983 05 44 29 -22 26 36 F7V 2.730 0.014 2.465 0.009 2.432 0.008 2.399 0.006 2.395 0.021
HR2015 05 44 47 -65 44 09 A7V 3.897 0.015 3.763 0.010 3.742 0.009 3.719 0.011 3.685 0.026
HR2020 05 47 17 -51 04 04 A5V 3.581 0.013 3.502 0.007 3.495 0.008 3.481 0.010 3.422 0.017
HD38921 05 47 22 -38 13 52 A0V 7.580 0.009 7.556 0.005 7.546 0.009 7.555 0.019

HR2007 05 48 35 -04 05 29 G4V 4.843 0.010 4.492 0.005 4.450 0.005 4.451 0.017

HR2085 05 56 24 -14 10 11 F1V 3.128 0.011 2.948 0.008 2.927 0.009 2.907 0.012 2.886 0.013
HD40335 05 58 13 +01 51 23 A0 6.565 0.007 6.478 0.007 6.470 0.009 6.468 0.012

HR2290 06 20 05 -48 44 15 G3V 5.520 0.015 5.189 0.013 5.141 0.012 5.123 0.010 5.118 0.060
HR2354 06 24 26 -63 25 39 G3III-IV 5.375 0.022 5.053 0.012 5.004 0.010 4.989 0.020 5.003 0.017
HR2318 06 24 45 -28 46 42 G2IV 5.284 0.029 4.971 0.013 4.923 0.008 4.908 0.015 4.850 0.056
HR2429 06 36 41 -19 15 18 K1III+ 2.282 0.013 1.742 0.012 1.654 0.013 1.576 0.018 1.695 0.023
HR2451 06 37 46 -43 11 45 B8III 3.337 0.011 3.360 0.012 3.391 0.012 3.412 0.010 3.380 0.026
HR2491 06 45 11 -16 41 58 A1V - 1.416 0.030 -1.401 0.030 -1.383 0.030 -1.345 0.005

HR2550 06 48 12 -61 56 42 A7IV 2.785 0.005 2.674 0.008 2.651 0.006



HD52298 06 57 45 -52 38 35 F5/F6V 6.019 0.022 5.749 0.012 5.718 0.008



HR2672 07 03 54 -49 35 09 A4IV 4.669 0.005 4.607 0.005 4.604 0.005 4.591 0.008

HR2667 07 03 58 -43 36 48 G3V 4.470 0.005 4.137 0.006 4.094 0.011



HR2668 07 03 59 -43 37 01 K0V 5.507 0.017 5.078 0.008 5.018 0.013 4.974 0.008 5.068 0.049
HR2701 07 10 14 -04 14 24 K0III 3.220 0.015 2.635 0.008 2.550 0.009 2.468 0.013 2.553 0.025
HR2882 07 30 43 -37 20 25 G4V 5.562 0.023 5.224 0.011 5.170 0.017 5.146 0.025 5.137 0.063
HD60778 07 36 12 -00 08 13 A1V 8.787 0.007 8.714 0.005 8.692 0.019 8.712 0.027

HR2970 07 41 15 -09 33 03 G9III 2.289 0.013 1.735 0.005 1.646 0.006 1.558 0.007 1.683 0.019
HR3018 07 45 36 -34 11 46 G0V 4.231 0.015 3.855 0.008 3.799 0.007



HR3090 07 53 18 -48 06 11 B0.5Ib 4.558 0.014 4.598 0.007 4.650 0.008



HR3138 07 57 43 -60 18 17 G0V 4.561 0.021 4.255 0.009 4.216 0.009 4.132 0.029

HR3176 08 07 46 +21 34 58 G1IV 4.219 0.009 3.898 0.010 3.835 0.007



HR3300 08 22 55 -52 07 27 A0V 5.906 0.013 5.902 0.005 5.914 0.009



HR3314 08 25 40 -03 54 22 A0V 3.932 0.015 3.932 0.010 3.944 0.009 3.938 0.010 3.950 0.012
HR3421 08 37 21 -40 08 53 G4IV-V 5.521 0.011 5.211 0.009 5.171 0.005 5.146 0.006

HR3476 08 43 40 -49 49 22 B0IIIn 5.575 0.023 5.649 0.005 5.719 0.005 5.795 0.016

HR3484 08 46 22 -13 32 51 G8III 2.817 0.015 2.326 0.006 2.249 0.010 2.172 0.005 2.237 0.019
HD75223 08 47 22 -39 47 59 A1V 7.316 0.014 7.301 0.016 7.295 0.006 7.279 0.011

HD77281 09 01 38 -01 28 35 A2 7.110 0.005 7.051 0.006 7.045 0.005 7.049 0.016

HR3614 09 04 09 -47 05 51 K2III 1.900 0.010 1.299 0.007 1.193 0.006 1.096 0.009 1.253 0.017
HR3613 09 05 58 +05 05 33 K2Iab: 3.022 0.018 2.387 0.008 2.279 0.006 2.154 0.012

HR3634 09 08 00 -43 25 58 K4Ib-II - 0.556 0.007 -1.375 0.007 -1.575 0.005 -1.745 0.007

HR3685 09 13 14 -69 43 07 A2IV 1.593 0.005 1.543 0.005 1.544 0.005 1.537 0.007

HR3718 09 21 30 -25 57 55 M0III 1.663 0.008 0.770 0.005 0.553 0.005 0.410 0.005

HR3785 09 31 39 -10 33 07 F0Vn 5.634 0.021 5.462 0.009 5.433 0.005



HR3842 09 38 01 -43 11 25 G8II 3.971 0.015 3.493 0.008 3.413 0.008 3.342 0.010 3.418 0.021
HD83844 09 40 38 -21 34 54 K0III 6.046 0.007 5.473 0.010 5.398 0.011 5.345 0.015

HR3862 09 42 16 -23 55 09 G0V 3.985 0.005 3.716 0.005 3.685 0.005 3.654 0.013

HR3871 09 44 12 -27 46 12 A8V+ 3.727 0.009 3.335 0.006 3.266 0.007 3.193 0.016 3.266 0.005
HR3903 09 51 29 -14 50 46 G6/G8III 2.620 0.008 2.135 0.009 2.051 0.006 1.987 0.006 2.037 0.016
HR3981 10 07 56 -00 22 17 A0III 4.492 0.006 4.495 0.005 4.510 0.005 4.536 0.009

HR3994 10 10 36 -12 21 10 K0III 2.012 0.012 1.529 0.007 1.429 0.006 1.362 0.006

HR4013 10 13 26 -33 01 57 G1V 5.362 0.008 5.047 0.007 5.003 0.011



HR4023 10 14 45 -42 07 21 A2V 3.772 0.012 3.752 0.008 3.752 0.008 3.746 0.008 3.741 0.029
HR4102 10 24 24 -74 01 52 F2IV 3.340 0.011 3.158 0.008 3.136 0.007 3.116 0.008 3.074 0.013
GJ390 10 25 13 -10 13 49 M0 6.973 0.009 6.286 0.005 6.069 0.005 5.844 0.008

HR4094 10 26 06 -16 50 06 K4III 1.326 0.005 0.538 0.005 0.375 0.011 0.250 0.011

HR4167 10 37 19 -48 13 31 F4IV+ 3.312 0.011 3.153 0.008 3.132 0.008 3.115 0.013 3.093 0.020
HR4232 10 49 37 -16 11 47 K0/K1III 1.090 0.011 0.381 0.009 0.285 0.018 0.171 0.011

HR4257 10 53 29 -58 51 13 K1III 2.234 0.005 1.704 0.005 1.621 0.005



HR4273 10 56 43 -37 08 10 K1III 2.972 0.005 2.426 0.005 2.336 0.005 2.246 0.013

HR4293 11 00 09 -42 13 33 A3IV 4.150 0.005 4.074 0.005 4.062 0.009 4.053 0.010

HR4325 11 06 33 -62 25 27 G8III 3.025 0.005 2.500 0.005 2.409 0.005 2.331 0.005

HD96620 11 06 55 -58 47 36 A0IV 5.526 0.016 5.366 0.010 5.345 0.011



HR4450 11 33 01 -31 51 25 G7III 2.045 0.010 1.559 0.005 1.471 0.005 1.391 0.005 1.469 0.009
HD101452 11 40 14 -39 08 47 A2 7.017 0.017 6.877 0.008 6.855 0.005 6.835 0.009

HD102200 11 45 34 -46 03 41 F2V 7.783 0.005 7.467 0.005 7.429 0.005



HR4520 11 45 37 -66 43 45 A7III 3.352 0.011 3.266 0.009 3.253 0.007 3.230 0.011 3.189 0.021
HR4523 11 46 38 -40 30 21 G5V 3.728 0.013 3.355 0.007 3.307 0.007 3.272 0.006 3.287 0.037
HR4620 12 08 15 -48 41 33 B9V 5.292 0.005 5.293 0.006 5.297 0.007 5.290 0.005

HR4623 12 08 24 -24 43 42 F0IV/V 3.408 0.016 3.233 0.016 3.212 0.010 3.186 0.010

HR4638 12 11 39 -52 22 06 B3V 4.325 0.012 4.391 0.009 4.445 0.010 4.469 0.008

HR4662 12 15 49 -17 32 32 B8III 2.772 0.014 2.793 0.007 2.817 0.007 2.828 0.005 2.862 0.031
HD106965 12 17 58 +01 34 31 A2 7.391 0.013 7.337 0.010 7.332 0.010 7.296 0.017

HR4695 12 20 22 +03 18 49 K0IIIb 3.014 0.016 2.322 0.005 2.213 0.009 2.122 0.011 2.304 0.007
HR4743 12 28 03 -50 13 49 B2V 4.372 0.005 4.441 0.005 4.517 0.010 4.578 0.009

HR4757 12 29 53 -16 30 48 B9.5V 3.038 0.009 3.041 0.007 3.061 0.005



HR4802 12 37 43 -48 32 28 A2V 3.749 0.015 3.707 0.013 3.706 0.010 3.691 0.013 3.656 0.013
HR4831 12 42 36 -48 48 45 K0III 2.913 0.006 2.377 0.018 2.280 0.005 2.201 0.005

HD110621 12 43 44 -44 40 30 F8 8.952 0.005 8.613 0.008 8.577 0.007



HR4889 12 53 26 -40 10 43 A7III 3.832 0.033 3.684 0.016 3.665 0.020 3.633 0.013

HR4903 12 54 59 -44 08 56 G1V 4.853 0.016 4.559 0.005 4.507 0.005



HR4933 13 03 33 -49 31 37 A0V 4.816 0.009 4.779 0.007 4.780 0.005 4.780 0.008

HR4989 13 14 17 -59 06 03 F7IV 4.012 0.014 3.721 0.010 3.680 0.010 3.646 0.012 3.641 0.028
HR5028 13 20 37 -36 42 40 A2V 2.723 0.011 2.704 0.009 2.705 0.008 2.699 0.010 2.675 0.014
HR5041 13 24 00 -64 32 07 G6II 3.148 0.012 2.676 0.005 2.597 0.007 2.533 0.006

HR5107 13 34 42 -00 35 47 A3V 3.190 0.019 3.117 0.005 3.099 0.012 3.085 0.014

HR5132 13 39 53 -53 27 58 B1III 2.815 0.008 2.912 0.005 2.993 0.005 3.055 0.005 3.049 0.012
HR5241 13 57 39 -63 41 10 K0III 2.957 0.018 2.374 0.016 2.274 0.006 2.192 0.005

HR5249 13 58 41 -44 48 11 B2IV-V 4.342 0.010 4.430 0.012 4.507 0.010 4.575 0.014 4.534 0.032
HR5384 14 23 14 +01 14 54 G1V 5.126 0.012 4.749 0.009 4.703 0.006 4.571 0.023 4.597 0.014
HR5444 14 36 19 -46 14 44 K3III 3.063 0.005 2.258 0.005 2.092 0.005 1.956 0.005

HR5487 14 43 03 -05 39 14 F2III 3.147 0.013 2.926 0.007 2.898 0.006



HD129655 14 43 46 -02 30 18 A2 6.864 0.018 6.740 0.007 6.714 0.005



HR5489 14 44 59 -35 11 30 A0V 4.894 0.010 4.845 0.012 4.843 0.013 4.839 0.006

HR5494 14 46 29 -47 26 27 A1V 5.663 0.030 5.612 0.015 5.611 0.005 5.611 0.013

HD130163 14 47 47 -39 55 34 A0V 6.885 0.019 6.857 0.011 6.861 0.006 6.856 0.011

HR5531 14 50 53 -16 02 27 A3IV 2.527 0.012 2.445 0.008 2.429 0.012 2.406 0.010

HR5649 15 12 18 -52 05 53 G8III 1.938 0.009 1.434 0.006 1.343 0.009 1.292 0.009 1.361 0.020
HR5685 15 17 01 -09 22 57 B8V 2.801 0.016 2.816 0.008 2.844 0.007 2.873 0.005 2.872 0.005
HR5670 15 17 31 -58 47 57 A3V 3.926 0.012 3.889 0.005 3.904 0.005 3.882 0.014

HR5699 15 21 56 -48 18 49 G4V 4.514 0.028 4.142 0.008 4.104 0.011



HR5824 15 40 17 -23 49 05 K3III 2.853 0.014 2.195 0.010 2.058 0.010 1.944 0.010 2.143 0.005
HR5897 15 55 10 -63 25 30 F2III 2.298 0.015 2.137 0.010 2.107 0.013 2.069 0.006 2.052 0.022
HR5917 15 55 30 -26 15 56 A3V 5.332 0.019 5.229 0.013 5.211 0.010



HR5962 16 03 13 -49 13 47 G8III 3.145 0.006 2.677 0.009 2.588 0.005 2.524 0.005

HR6070 16 18 18 -28 36 46 A0V 4.831 0.005 4.799 0.016 4.813 0.006 4.807 0.006 4.717 0.077
HR6072 16 19 51 -50 09 17 G8III 2.318 0.020 1.770 0.012 1.667 0.012 1.589 0.019 1.720 0.021
HR6084 16 21 11 -25 35 33 B1III 2.495 0.011 2.406 0.012 2.407 0.011 2.406 0.013 2.385 0.009
HR6094 16 24 01 -39 11 35 G5V 4.314 0.021 3.976 0.014 3.928 0.005 3.891 0.006 3.874 0.029
HR6136 16 28 34 +00 39 58 K4III 2.973 0.032 2.219 0.012 2.052 0.010 1.921 0.010 2.189 0.005
HR6147 16 31 08 -16 36 44 G8/K0III 2.817 0.014 2.353 0.009 2.265 0.009 2.204 0.014 2.289 0.020
HR6241 16 50 12 -34 17 23 K2.5III 0.411 0.019 -0.181 0.008 -0.288 0.019 -0.364 0.006 -0.216 0.005
HR6378 17 10 22 -15 43 34 A2.5Va 2.325 0.016 2.283 0.015 2.274 0.013 2.257 0.015 2.229 0.016
HD156005 17 16 48 -37 24 34 K2III: 5.847 0.010 5.033 0.008 4.861 0.005



HR6441 17 20 35 -19 19 52 G1V 5.520 0.010 5.219 0.012 5.168 0.013



HR6417 17 22 00 -67 46 13 K2III 2.776 0.005 2.121 0.005 1.995 0.005 1.898 0.005

HR6537 17 35 40 -46 30 18 A0V 4.578 0.010 4.539 0.005 4.536 0.005 4.524 0.005

HR6572 17 41 16 -46 55 18 A0V 5.739 0.013 5.728 0.005 5.738 0.005 5.726 0.005

HD160617 17 42 50 -40 18 55 Fw 7.720 0.005 7.380 0.005 7.343 0.008



HD161743 17 48 58 -38 07 06 B9IV 7.667 0.011 7.638 0.008 7.641 0.009



HR6630 17 49 51 -37 02 37 K2III 1.269 0.021 0.637 0.007 0.524 0.006 0.436 0.010 0.584 0.029
HR6682 17 57 48 -41 42 58 M0III 1.823 0.012 0.938 0.005 0.735 0.005 0.594 0.005

HR6698 17 59 02 -09 46 19 G9III 1.752 0.014 1.241 0.011 1.150 0.008 1.086 0.010 1.178 0.009
HR6736 18 03 52 -24 21 38 O8Iab: 5.817 0.012 5.773 0.012 5.796 0.007 5.819 0.017 5.802 0.054
HR6746 18 05 49 -30 25 17 K0III 1.285 0.005 0.722 0.005 0.639 0.005 0.595 0.005 0.667 0.005
HR6748 18 06 23 -36 01 12 G5V 4.898 0.014 4.581 0.006 4.537 0.009



HD166913 18 16 27 -59 24 05 F6:Vw 7.261 0.007 6.949 0.005 6.913 0.005



HR6879 18 24 10 -34 22 59 B9.5III 1.796 0.011 1.761 0.008 1.758 0.009 1.739 0.009 1.717 0.012
HR6893 18 25 55 -33 56 43 B5IV 6.397 0.020 6.411 0.011 6.444 0.013



SAO245532 18 32 08 -59 27 42 F9 8.884 0.005 8.612 0.006 8.567 0.005



HR6951 18 33 30 -42 18 44 G8III 3.014 0.027 2.497 0.005 2.402 0.008 2.328 0.006

HR7120 18 55 07 -22 40 16 K1Ib/II 2.869 0.016 2.177 0.011 2.040 0.011 1.925 0.009 2.167 0.018
HR7136 18 57 34 -39 49 26 A5IV/V 5.941 0.024 5.838 0.026 5.820 0.024



HR7188 19 03 06 -42 05 40 B9.5V 4.797 0.009 4.788 0.011 4.799 0.005 4.799 0.005

HR7217 19 04 41 -21 44 27 K0III 2.115 0.018 1.580 0.005 1.489 0.007 1.408 0.012

HR7236 19 06 15 -04 52 53 B9Vn 3.616 0.012 3.624 0.009 3.650 0.007 3.681 0.007 3.676 0.024
HR7254 19 09 28 -37 54 12 A2V 4.030 0.016 3.993 0.005 3.990 0.005 3.985 0.005

HR7264 19 09 46 -21 01 23 F2II/III 2.140 0.013 1.920 0.010 1.871 0.010 1.813 0.007 1.806 0.012
HR7259 19 10 02 -39 20 25 K0II 2.227 0.009 1.633 0.005 1.509 0.005 1.396 0.011

HR7330 19 21 29 -34 58 57 G5V 5.396 0.020 5.052 0.012 4.988 0.007



HR7340 19 21 40 -17 50 51 F0III/IV 3.554 0.005 3.431 0.005 3.406 0.005



HR7343 19 23 13 -44 47 56 F2III 3.605 0.015 3.406 0.016 3.365 0.011 3.342 0.007

HR7429 19 34 05 +07 22 52 K3IIIb 2.550 0.012 1.917 0.019 1.803 0.015 1.732 0.005 1.882 0.008
HR7446 19 36 53 -07 01 39 B0.5III 4.991 0.010 5.000 0.012 5.028 0.010 5.055 0.010 4.996 0.040
HD188112 19 54 31 -28 20 22 B9V 10.708 0.006 10.787 0.005 10.860 0.017



HR7581 19 55 15 -41 52 09 K0II-III 2.327 0.008 1.706 0.009 1.600 0.013 1.528 0.014

HR7652 20 03 33 -37 56 22 K5III 2.432 0.010 1.667 0.011 1.521 0.005 1.414 0.012

HD190285 20 05 12 -26 48 47 A0V 7.053 0.005 7.004 0.011 6.999 0.012



HR7644 20 05 25 -67 18 42 G3V 4.966 0.028 4.605 0.014 4.566 0.009



HR7665 20 08 33 -66 09 59 G7IV 2.346 0.014 2.011 0.015 1.939 0.012 1.878 0.016

HR7710 20 11 18 -00 49 18 B9.5III 3.348 0.009 3.350 0.011 3.369 0.010 3.378 0.005 3.387 0.023
HR7754 20 18 03 -12 32 42 G6/G8III 2.077 0.005 1.577 0.010 1.488 0.005 1.428 0.008 1.509 0.007
HR7773 20 20 40 -12 45 32 B9IV 4.842 0.015 4.846 0.011 4.859 0.010 4.893 0.006 4.887 0.040
HR7869 20 37 34 -47 17 33 K0IIICN 1.481 0.005 0.934 0.007 0.851 0.005 0.785 0.005 0.883 0.005
HR7936 20 46 06 -25 16 08 F5V 3.385 0.008 3.174 0.013 3.142 0.014 3.118 0.005

HR7950 20 47 40 -09 29 43 A1V 3.744 0.014 3.703 0.020 3.707 0.016 3.702 0.010 3.676 0.022
HR8042 21 02 12 -43 00 02 G3IV+ 5.511 0.012 5.141 0.010 5.085 0.007 5.053 0.008 5.066 0.014
HR8100 21 12 13 -40 15 59 F5IV 5.055 0.011 4.827 0.005 4.800 0.005



HD201916 21 12 35 +00 53 35 F0 8.047 0.015 7.853 0.013 7.828 0.007



HD201941 21 12 45 +02 38 35 A2 6.741 0.005 6.653 0.005 6.640 0.005



HR8117 21 15 14 -40 30 23 K2III 4.348 0.013 3.721 0.011 3.617 0.009



HD202964 21 20 21 -38 24 16 F3V 8.652 0.005 8.323 0.005 8.280 0.012



HR8167 21 22 15 -16 50 05 G8III 2.826 0.018 2.351 0.012 2.271 0.011 2.204 0.009 2.247 0.016
HR8181 21 26 26 -65 22 39 F6V 3.287 0.010 2.986 0.008 2.954 0.010 2.922 0.011 2.916 0.016
HR8205 21 26 28 +01 06 20 F5V 5.317 0.005 5.087 0.005 5.062 0.005 5.034 0.005

HR8204 21 26 40 -22 24 42 G4Ibp 2.382 0.021 1.952 0.007 1.865 0.011 1.794 0.007 1.857 0.011
HR8222 21 29 59 -19 08 50 F3V 5.817 0.006 5.600 0.005 5.565 0.005 5.551 0.005

HR8232 21 31 33 -05 34 16 G0Ib 1.577 0.016 1.204 0.007 1.153 0.005 1.060 0.012 1.072 0.010
HD205772 21 38 41 -41 02 53 A5IV/V 7.797 0.010 7.690 0.007 7.676 0.009 7.695 0.005

HR8278 21 40 05 -16 39 44 A7mp 3.217 0.008 3.082 0.005 3.056 0.005 3.041 0.006 3.030 0.009
HR8283 21 41 33 -14 02 36 G2V 4.012 0.011 3.654 0.005 3.602 0.005 3.578 0.007 3.563 0.005
HD207288 21 48 18 -17 37 G8V 8.838 0.005 8.394 0.005 8.329 0.005



HR8353 21 53 55 -37 21 53 B8III 3.242 0.016 3.274 0.008 3.311 0.005 3.336 0.007 3.333 0.013
HR8387 22 02 57 -56 45 03 K4.5V 2.872 0.020 2.290 0.016 2.194 0.005 2.126 0.007 2.181 0.013
HR8414 22 05 47 -00 19 11 G2Ib 1.546 0.010 1.067 0.005 0.967 0.005 0.888 0.006 1.007 0.010
HR8425 22 08 13 -46 57 33 B7IV 2.052 0.026 2.084 0.011 2.117 0.007 2.149 0.009 2.148 0.027
HR8431 22 08 23 -32 59 18 A2V 4.423 0.006 4.379 0.006 4.372 0.005 4.362 0.011 4.344 0.015
HD210427 22 10 48 -26 53 G1V 9.306 0.021 8.975 0.022 8.917 0.016 8.946 0.021

HD210863 22 13 26 -08 13 46 G0 8.615 0.013 8.299 0.005 8.260 0.005



HR8477 22 14 36 -41 22 15 G5V 5.100 0.014 4.743 0.013 4.695 0.012 4.683 0.006 4.678 0.010
HD211131 22 15 30 -29 07 G8V 8.535 0.009 8.061 0.010 8.000 0.025



HD211290 22 16 24 -14 34 K1III: 7.933 0.005 7.329 0.005 7.220 0.005



HR8499 22 16 50 -07 46 59 G8III 2.641 0.011 2.133 0.009 2.048 0.013



HR8531 22 24 55 -57 47 34 G3IV 4.173 0.006 3.805 0.005 3.749 0.005 3.709 0.006 3.722 0.009
HD212874 22 27 19 +04 02 51 A2 9.092 0.005 8.928 0.005 8.908 0.006



HR8551 22 27 51 +04 41 59 K0III 3.027 0.016 2.413 0.011 2.318 0.013



HR8556 22 29 16 -43 29 44 G7III 2.364 0.009 1.838 0.007 1.742 0.006 1.664 0.005 1.761 0.006
HD214497 22 38 48 -14 48 F6V 9.259 0.018 8.973 0.007 8.937 0.005



HD216009 22 49 51 -44 25 26 A0V 8.012 0.020 7.968 0.006 7.966 0.010



HR8700 22 53 37 -48 35 50 G0V 5.013 0.011 4.699 0.009 4.657 0.009 4.636 0.013 4.638 0.012
HR8709 22 54 39 -15 49 14 A3V 3.148 0.015 3.088 0.010 3.081 0.010 3.072 0.008 3.059 0.019
HR8701 22 54 40 -70 04 30 G2.5IV 4.973 0.017 4.641 0.007 4.591 0.005 4.566 0.009 4.550 0.019
HR8728 22 57 38 -29 37 12 A3V 1.055 0.010 1.020 0.005 1.020 0.005 1.019 0.010 1.004 0.006
HR8781 23 04 45 +15 12 21 B9III 2.570 0.016 2.550 0.009 2.526 0.014 2.548 0.012 2.546 0.031
HD218814 23 11 42 -56 47 23 A6V 9.367 0.010 9.265 0.005 9.246 0.005



HR8848 23 17 26 -58 14 13 F1III 3.242 0.007 3.013 0.008 2.981 0.008 2.951 0.007 2.922 0.005
HD219761 23 18 46 -47 26 07 B9V 6.650 0.010 6.624 0.024 6.635 0.024 6.615 0.011

HR8892 23 22 59 -20 05 57 K0III 2.124 0.010 1.490 0.006 1.393 0.010 1.313 0.012 1.426 0.019
HD221462 23 32 27 -24 55 55 G3V 8.643 0.016 8.295 0.009 8.250 0.005



HR8959 23 37 51 -45 29 32 A2V 4.601 0.011 4.548 0.009 4.545 0.009



HR8998 23 44 12 -18 16 37 B9V 5.400 0.012 5.402 0.012 5.424 0.010



HR9076 23 59 55 -65 34 37 B9IV 4.616 0.007 4.623 0.006 4.642 0.005 4.636 0.005 4.660 0.043