Overview

VISTA, built by a large UK-based consortium, is a 4-m class wide field survey telescope for the southern hemisphere. VISTA is located at ESO's Cerro Paranal Observatory in Chile on its own peak about 1500m from the four VLTs and the VST. The telescope has an altitude-azimuth mount, and quasi-Ritchey-Chretien optics with a fast f/1 primary mirror giving an f/3.25 focus to the instrument at Cassegrain. Shape and position of the mirrors are actively controled by high and low order curvature wave front sensors (WFS) located inside the instrument focal plane. The low order WFSs are used simultaneously, during the scientific observations. Equipped with a near infrared camera it will cover a 1.65 degree diameter field of view with a loosly packed detector mosaic of 67 million pixels of mean size 0.339 arcseconds. Broad band filters are available for the Z,Y,J,H and Ks bands and a narrow band filter at 1.18 micron. The point spread function (PSF) of the telescope+camera system (including pixels) is expected to have a full width at half maximum (FHWM) of 0.51 arcsecs.

Public Surveys

During the first year VISTA will be exclusively used for six public surveys, which have been reviewed by the "Public Survey Panel" (PSP), and recommended by the ESO Observing Programme Committee (OPC), following the "Call for Proposals for VISTA Public Surveys" (issued in January 2006).

VISTA Data Flow System

The mean VISTA data volumes are high (estimated ~315GigaByte on a typical night). Individual pawprints extracted from the ESO archive can be passed through a calibration pipeline at Garching that will remove instrumental artefacts, and produce astrometrically and photometrically calibrated single pawprints. These will be used primarily for the instrument calibration and monitoring purposes.

The UK-based VISTA Data Flow System (VDFS) receives a copy of all VISTA raw data by agreement with ESO, and is required to fully respect the proprietary rights assigned by ESO to observations. The VDFS will further combine the pawprints into tiles, extract sources and place these in a VISTA Science Archive where authorized users can interrogate the data and use tools to combine it into survey products. Survey data processing by the VDFS is not guaranteed. Survey PIs must contact the VDFS project leader to further coordinate the steps.

The final Public Survey data products are to be delivered to ESO for integration into the ESO SCIENCE archive. Guidelines for the submission of data products are avaliable on the ESO Public Surveys Web pages.